background image

Rugged, Reliable, Mobile, Secure

TM

1-800-260-9800

www.CRU-DataPort.com

Limited Product Warranty 

CRU-DataPort (CRU) warrants the Data Express DE110 to be free of sig-
nificant defects in material and workmanship for a period of five years 
from the original date of purchase. CRU’s warranty is nontransferable 
and is limited to the original purchaser.

Limitation of Liability

The warranties set forth in this agreement replace all other warranties. 
CRU expressly disclaims all other warranties, including but not limited 
to, the implied warranties of merchantability and fitness for a particular 
purpose and non-infringement of third-party rights with respect to 
the documentation and hardware. No CRU dealer, agent or employee 
is authorized to make any modification, extension, or addition to this 
warranty. In no event will CRU or its suppliers be liable for any costs 
of procurement of substitute products or services, lost profits, loss of 
information or data, computer malfunction, or any other special, indirect, 
consequential, or incidental damages arising in any way out of the sale 
of, use of, or inability to use any CRU product or service, even if CRU has 
been advised of the possibility of such damages. In no case shall CRU’s 
liability exceed the actual money paid for the products at issue. CRU 
reserves the right to make modifications and additions to this product 
without notice or taking on additional liability. 

Certification

EMI Standard:  

FCC Part 15 Class B, CE

EMC Standard:  

EN55022, EN55024

FCC Certification

This device has been tested and found to comply with the limits 
for a Class B digital device, pursuant to Part 15 of the FCC rules. 
Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2.  This device must accept any interference receive including 

interference that  may cause undesired operation.

Register your product at www.CRU-DataPort.com 

A7-110-0005 Rev. 3.0

Selecting the Unit ID Number:

 Use the alignment tool (provided) to 

select the ID number of the disk drive.

NOTE: 

The lock on the Data Express receiving frame functions as 

a lock and a DC power switch for the carrier unit. The lock MUST 
be engaged (turned counterclockwise) in order to supply power to 
the carrier and installed drive unit.

Figure 3: Receiving Frame Unit ID Number and Activity Display

In the event of a fan failure the display window will flash “F” and the 
SCSI ID number.  For information to replace your fan please contact 
CRU-DataPort technical support at 800-260-9800 x 4 or email at Sup-
port@CRU-DataPort.com.

Figure 4: Unit ID Select Switch Location

Drive Carrier 

Guide

Typical Data Express 

Receiving Frame

Unit ID Select 

Rotating Switch

Carrier Removed from 

Receiving Frame

Carrier Installed

(unlocked)

Carrier Installed 

(locked)

Fan Failure

The number “2” shown above is for illustration purposes only. It can be any 

valid unit ID number. The letter “u” and “F” will appear as illustrated. 

Activity 

Indicator

Reviews: