2 Receiving Frame Motherboard

Remote Unit ID Selection:

 Pins 1-8 are provided for remote unit ID selection for 

the computer system or expansion chassis. Remote ID selection requires that the 

unit ID switch located on the inside of the receiving frame be set to “0” (onboard ID 
selection is set with a switch located on the inside of the receiving frame as shown 

in Figure 10).

3 Typical SCSI ID Pin Connections

The figure below illustrates a typical SCSI ID select connection to a drive with 2mm 
ID select pins. The wires on the wire harness connect to the positive pin (or signal 
pins) on the disk drive. In some cases, the drive manufacturer will label the signal 
pins as Pin 1, 3, 5, 7, (instead of 0, 1, 2, 3 as shown in Figure 3). Also, in some cases, 
the even-numbered Pins 2, 4, and 6 are used for Ground.

Attach the ID select cable to the drive using the 2mm connectors. Align the “ID0” 

pin with the 

black

  wire.  Attach  the  1.25mm  connector  on  the  other  end  of  the 

ID select cable to the 1.25mm connector (J3B) provided on the signal distribution 

board, located inside the carrier. Refer to the manufacturer’s documentation to 

disable termination on the drive.

4 Selecting the Unit ID Number

Use the alignment tool provided to select the ID number of the disk drive.

NOTE:  The lock on the Data Express receiving frame functions as a lock and 

a DC power switch for the carrier unit. The lock MUST be engaged (turned 

counterclockwise) in order to supply power to the carrier and installed drive 

unit.

NOTE:    No  onboard  termination  is  provided  on  the  DE200i-SWU2.  External 
termination must be provided.