Temperature Sensors Locations For The
MTC Model Units
Loop water out sensor
•
Located on the water outlet pipe on the top
of the plate coil
•
This sensor is used to sense the Loop water
low temperature limit (Freeze sensor)
•
Sensor is marked (Supply)
Common loop water return sensor
•
Located on the water inlet pipe on the
bottom of the plate coil
•
The chiller cycles on it’s set points by this
sensor
•
All chillers read off of the #1 chiller.