5-22
520 Express Series
520 Express Series
OVERBOARD DISCHARGE
A valve is installed between the marine toilet
and the waste holding tank. The valve can
direct the flow of waste to the holding tank,
or to an outlet seacock for overboard
discharge of waste.
IMPORTANT
Overboard discharge of waste
should only be used in approved
areas. It is your responsibility to
comply with local regulations
regarding the discharge of waste.
To operate overboard discharge, the valve
lever must be in the overboard position and
the waste water outlet seacock must be
open. Close the outlet water seacock when
not in use.
MACERATOR PUMP
There has been an extra hose added to your
waste tanks; this is for the macerator. The
macerator pump is located on the forward
side of both the forward and aft waste tanks.
In this configuration all waste is flushed from
the head to the holding tank.You are able to
use either the pumpout feature by using the
deckplate, or the macerator to pump waste
from the holding tank directly overboard.
IMPORTANT
Overboard discharge of waste
should only be used in approved
areas. It is your responsibility to
comply with local regulations
regarding the discharge of waste.
To pump out the holding tank using the
macerator pump:
1. Open the 1" seacock labeled
MACERATOR DISCHARGE.
CAUTION
DO NOT run the pump dry. Running
the pump when there is no waste to
pump out of the holding tank will
shorten the life of the pump.
2. Activate the macerator pump. Close the
circuit marked MACERATOR from the
DC panel. A full tank can be emptied in
approximately three minutes.
3. Close the macerator discharge seacock
after the pumpout is complete.
CSR161-13
CSR161-14