12
ANTIWEAR HYDRAULIC OILS
Hydraulic System Operating
Temperature Range*
ISO Viscosity
Grade
-21°C to 60°C(- 5°F to 140°F)
22
-15°C to 77°C( 5°F to 170°F)
32
- 9°C to 88°C( 15°F to 190°F)
46
- 1°C to 99°C( 30°F to 210°F)
68
CRANKCASE OILS
Hydraulic System Operating
Temperature Range
SAE Viscosity
Designation
-23°C to 54°C(-10°Fto130°F)
5W,5W-20,5W-30
-18°C to 83°C( 0°F to 180°F)
10W
-18°C to 99°C( 0°F to 210°F)
10W-30, 10W-40
10°C to 99°C( 50°F to 210°F)
20-20W
Lubrication and Maintenance
SUITABLE TYPES OF OIL
Crankcase oil having letter designation SC, SD, SE, or SF per SAE J183 JUN86. Note that one oil may
meet one or more of these designations.
ANTIWEAR HYDRAULIC OIL - These are produced by all major oil suppliers and should consist of good
quality base stocks compounded with antiwear, antioxidation, and antirust additives.
CERTAIN OTHER TYPES OF PETROLEUM OIL are suitable if they meet the following provisions:
1. Contain the type and content of antiwear additives found in the above designated
crankcase oils.
2. Have sufficient chemical stability for mobile hydraulic system service.
3. Meet the viscosity recommendations shown in the flowing tables.
OIL VISCOSITY RECOMMENDATIONS
*Temperatures shown are cold(ambient)start-up to maximum operating. During cold start-up, avoid
high-speed operation of hydraulic components until the system is warmed up to provide adequate
lubrication.
CLEANLINESS
Thorough precautions should always be observed to insure the hydraulic system is clean:
1. Clean(flush)entire system to remove paint, metal chips, welding shot, etc.
2. Filter each change of oil to prevent introduction of contaminant into the system.
3. Provide continuous oil filtration to remove sludge and products of wear and corrosion generated
during the life of the system.
4. Provide continuous protection of the system from entry of airborne contamination by sealing the
system and/or by proper filtration of the air.
5. Maintain the proper oil level and regularly service filters, breathers, and reservoirs. The importance
of these precautions cannot be overemphasized.
6. Take precautions to prevent moisture contamination. Change fluid whenever contamination occurs
because even small amounts of water can have a substantial effect on system performance, as well
as induce corrosion and oil breakdown.
Summary of Contents for COTTON MODULE BUILDER
Page 1: ...COTTON MODULE BUILDER OWNER S MANUAL 00081000 02 08 ...
Page 28: ...26 Bridge Assembly Chain Drive ...
Page 30: ...28 Bridge Assembly Chainless ...
Page 34: ...32 Hydraulic Lines Chain Drive ...
Page 36: ...34 Hydraulic Lines Chainless ...
Page 42: ...P O Box 1438 Dodge City Kansas 67801 620 227 7106 ...