5
Installation Instructions: Three Stage Filtration System
FIL
-
W300005
5.
After all tubing, fittings, connections, and flow directions are verified on the filter kit, inspect
for damage before attaching the product water tubing to the filter kit as shown below. Be
sure to follow the inlet and outlet direction as outlined in these instructions. Install filter set
to the filter clips inside the Crystal Pro as shown below.
Your Crystal Pro Water Dispenser is supplied with a electronic leak detector. If excess water has
accumulated around the base, the leak detector will need to be completely dried before proper
operation. The sensor is located just in front of the right front compressor foot.
A pressure regulator must be installed for this installation with a set point no higher then 65
PSIG
Place cooler in service by connecting water supply and electrical supply as outlined in the
Crystal Pro installation instructions, check for leaks and replace filter access door by pushing it
down and back into place.