The Indigo 2AE/2SE frame rear view with EMC covers fitted.
The Indigo 2AE/2SE frame showing the use of EMC covers and the use of single, double and
quad rear connectors
Warning
: To maintain product safety and EMC compliance the rear of the frame should be
filled with Crystal Vision rear connectors and/or EMC covers and held in place with
fixing screws before power is reapplied.
2.8 Indigo power supplies
The Indigo 2AE/2SE frame is supplied with the 160W rated PSU-160i. It is possible to use the
older PSU-75i and PSU-150i but it is preferred that these are not mixed in any one frame.
PSU-160i - top view
Note
:
Care should be taken if mixing power supply types. It is not recommended to combine the
PSU-75i with anything other than a second PSU-75i. The Indigo power supply modules are
not compatible with similar PSUs used in FR2AV and FR1AV frames.
Monitoring power supply status
A signal from the each of the power supplies is routed through the frame wiring to the front panel
electronics. This allows an indication by the UPPER PSU LED and LOWER PSU LED of the
status of one or both power supplies.