Crystal Vision
Introduction
The following LED status indications may be seen:
LED
Colour
Notes
Front Fan
Unlit
Green
Red
Door open
Normal operation
Change the panel fan
PSU Fan
Unlit
Green
Red
Door closed and fan idle
Door open and fan operational
Change PSU fan
Upper PSU
Unlit
Green
Red
No upper PSU detected
Normal operation
Change upper PSU
Lower PSU
Unlit
Green
Red
No lower PSU detected
Normal operation
Change lower PSU
Temp
Green
Red
Normal operation
Internal temperature too high (approx. 65
0
C)
Comms
No function*
*Note
: Serial RS422 control from Statesman or third party applications is no longer supported.
All connections should be made via Ethernet. Crystal Vision AE and SE frames running v4.6
software or later support VisionWeb, Statesman Lite, ASCII and HTTP/JSON control protocols.
An optional SNMP licence can be purchased to enable control and monitoring via SNMP.
Contact Crystal Vision Support for protocol documentation.
Indigo 2AE and 2SE User Manual R1.17
6