Crystal Vision
Specification
Indigo 4 User Manual R1.7
43
09/08/2012
5 Specification
Indigo 4U frame
General
Dimensions:
482mm wide (19 inches), 176mm high (4U), 425mm deep. Weight 10 kg
Power requirements:
85 to 264 Volts, 47 to 400Hz
Operating conditions:
0 to 40 degrees C non-condensing
Ventilation front to sides, without air filters
Power supply:
Up to four plug-in power supplies (160 Watt PSU-160i)
Module control
Remote options:
Six control lines per module. Assigned on module (eg. GPI or RS422/RS232)
Contact open/closure for any power supply or frame fault condition (supply out
of range or failure, fan too slow or fail, over-heat)
RS485 loop system for front panel to all modules and rear connection (rear
connection by way of 26-pin high density D-Type connector and RJ45
connector)
Second serial port available for Statesman control (connection via 26-pin high
density D-Type connector and RJ45 connector)
REMIND active display control of passive frame
Ethernet control capable option