2.2 Frame connectors
The following connectors are available at the rear of the frame:
Connector
Function
Notes
IEC (top)
Upper PSU AC input
85 to 264V, fuse under flap
IEC (bottom)
Lower PSU AC input
85 to 264V, fuse under flap
Upper frame
Remote 1
GPI and DC out
Refer to pinout tables
Remote 2
GPI, PSU 2 (upper PSU) alarm relay and DC
out
Refer to pinout tables
Remote 3
GPI and DC out
Refer to pinout tables
Remote 4
GPI and PSU 4 alarm relay
Refer to pinout tables
Lower frame
Remote 5
GPI and DC out
Refer to pinout tables
Remote 6
GPI, serial/Statesman, PSU 3 alarm relay and
DC out
Refer to pinout tables
Remote 7
GPI and DC out
Refer to pinout tables
Remote 8
GPI and PSU 1 (lower PSU) PSU alarm relay
Refer to pinout tables
Statesman
RS422
Statesman RS422 control using CAT-5
cabling
Refer to pinout tables
RS422 in/bus
RS422 control using CAT-5 cabling
Refer to pinout tables
Ethernet
Ethernet control using CAT-5 cabling
Refer to pinout tables
All frame connectors are grouped together behind the PSU modules at the rear of the
frame.
Connecting mains cables
The Indigo 4 frame is powered by connecting an IEC power cord(s) to the upper and/or
lower IEC connectors depending on the number of installed power supply modules.
Mains cables that are used must have a minimum current rating of 6A and be fitted with
an IEC 320 female connector; include a protective ground connection and meet relevant
local safety standards.
Tip:
To reduce the risk of electric shock, if two power supply cords are used plug each power
supply cord into separate branch circuits employing separate service grounds.
Note:
The fuse holder is part of the mains inlet. The mains cable must be disconnected before
the fuse can be accessed. Replace the fuse only with one of the same type and rating.
Refer to the Maintenance section of the trouble shooting guide for more information.