4.5 Transmitting an IP Flow
M-VIVID transmits ST 2022 or ST 2110-20 video over IP flows using the 10GbE network
interfaces on the VR04, VR06 or VR07 Vision frame rear connector. Typically Eth 1 is used
for receiving and transmitting the ‘primary’ IP flows, with Eth 2 being used for the ‘protect’ in -7
protect applications.
The following example shows an M-VIVID configured to transmit Output 1 using ST 2110-20
GPM Protect protocol. When selecting a protect protocol it is necessary to configure both the
‘Network Out’ and ‘Protect Network Out’.
M-VIVID Output 1 IP Flow Out
The controls highlighted in the above configuration show Output 1 of the M-VIVID routing
Input 1 to Ethernet Interface 1:3 and 2:3 using ST 2110-20 GPM Protect protocol. In this
example multicast destination addresses are being used for the main and protected flows