Page 11 of 15
Disinfecting the Unit
If unit has been turned off or un-used for an extended period, disinfecting the unit and water
lines is recommended before re-using.
Disconnect power, turn off water supply and drain unit following servicing instructions.
Mix a soapy water solution and use a syringe or funnel to pour solution into vessel.
Reconnect vessel to water supply but do not turn power on.
Open water supply and faucet and allow unit to flush until water no longer suds.
System Limitations
AquaPro UV systems are designed to operate continuously and should not be switched on
and off frequently. Doing this will shorten life of the lamp.
Lamps, quartz sleeves and o-rings should be changed yearly. Lamp may still be working but
light emitted may not kill bacteria as well as it should after a year.
Lamp life
9,000 hours (approx. 1 year)
Lamp Intensity
130 µW/cm² @ 1m
Working pressure
100 psi
Flow rate
12 gpm
Summary of Contents for 12 GPM
Page 8: ...Page 8 of 15...
Page 9: ...Page 9 of 15 Wiring Diagram...
Page 15: ...Page 15 of 15 Notes...