Page 7 of 15 

 

Connect the female 4-pin plug from the ballast to the pins on the lamp. 
 
 
 
 
 
 
 
 
 
Place the cover over the end of the UV unit. 
 
 
 
 
 
 
 
 
 
Connect the unit to a power source, turn water supply on and switch on the power. CHECK 
FOR LEAKS!
 
 
The light on the ballast should come on and turn green. 
 

(A red light on the ballast indicates a failed lamp and/or ballast. Turn the unit off and 
check your lamp connection. If red light remains, replace the lamp and check. If still 
not working, replace ballast as well.) 

 
Mount the UV system into the brackets. 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AQUA PRO 1 GPM

Page 1: ...ULTRAVIOLET STERILISER INSTALLATION MAINTENANCE BOOKLET Crystal Clear Purification Systems Pty Ltd 81 Torrens Road BROMPTON SA 5007 Australia t 08 8340 4344 e cc crystalclearaustralia com w www crysta...

Page 2: ...to avoid possible electric shocks DO NOT attempt to repair the system yourself Contact an authorized service facility for service 5 DO NOT operate the system if it has a damaged cord or plug if it is...

Page 3: ...t does not reduce sediments which effects the efficiency of the UV lamp Water Quality Parameters Water quality is extremely important for the performance of your UV system The following levels are rec...

Page 4: ...Page 4 of 15 Components Checklist Stainless Steel Vessel Quartz Sleeve w o rings Pre installed in vessel Ballast 14W Lamp Tube x F Elbow x2 Bracket x2...

Page 5: ...al with the lamp connector on top This is to prevent water damage from occurring on the lamp pins and connector The ballast should be mounted horizontally either above or beside the chamber to prevent...

Page 6: ...le elbow fittings to inlet and outlet ports of the unit Connect fittings into water line or onto a water filter system Open water supply to the unit and open faucet Once water is pouring out of the fa...

Page 7: ...turn water supply on and switch on the power CHECK FOR LEAKS The light on the ballast should come on and turn green A red light on the ballast indicates a failed lamp and or ballast Turn the unit off...

Page 8: ...Page 8 of 15...

Page 9: ...s and disconnect inlet and outlet elbows from chamber Tip the unit and drain as much water as possible into a bucket Remove end cover from chamber disconnect wire 4 pin plug from lamp and carefully re...

Page 10: ...sel to water supply but do not turn power on Open water supply and faucet and allow unit to flush until water no longer suds System Limitations AquaPro UV systems are designed to operate continuously...

Page 11: ...est source water for turbidity may need better pre filtration HEATED PRODUCT WATER Infrequent use of water o Run water until it returns to ambient temperature CLOUDY WATER Air in lines o Run water unt...

Page 12: ...our 24 hours of delivery A copy of the original invoice must be presented for any Warranty claim as proof of purchase The faulty item must be returned to Crystal Clear if such a request is made This l...

Page 13: ...Replaced Filters changed Yes Replace next service Next Service Due ____ ____ ____ 3rd Service ____ ____ ____ Serviced By ________________________ Lamp changed Yes No Quartz sleeve condition OK Cleaned...

Page 14: ...Page 14 of 15 Notes...

Page 15: ...Page 15 of 15 Notes...

Reviews:

Related manuals for AQUA PRO 1 GPM