Clamp-on amp sensor 0-1000A 

Clamp-on amp sensor 0-1000A 

English, V1.3, 05.01.11 

English, V1.3, 05.01.11 

0970 0033 

0970 0033 

 Introduction 

 Operation manual 

The Probe is a clamp-on AC current probe that is designed and tested according to EN 

61010-1:2002 and EN 61010-2-032:2002 (Overvoltage Category IV)

Safety Require-

ments for Hand-held Current Clamps for Electrical Measurement and Test, the EMC 
Directive (EN 61326-1:2006 and EN 61326-2-2:2006), and other safety standards (see 
“Safety Specifications”).

 

Warning 

Before using this Meter, read the following safety information carefully. If the Meter is not 
used as described in the manual, the safety features of the Meter might be severely im-
paired. 

Observe the International Electrical Symbols listed below. 

           WARNING! Risk of electric shock.        

           CAUTION! 

    

Equipment is protected throughout by Double Insulation or Reinforced Insulation. 

Read the following safety information carefully before attempting to operate or service 
the current probe. 

• 

Never use the Probe on circuits with voltages higher than 600V rms 

• 

Keep your fingers behind the barrier (hand guard)

 

• 

Be extremely cautious when clamping around uninsulated conductors or bus bars. 
Accidental contact with the conductor could result in electric shock.

 

• 

Check surface of the Probe jaws; these should be free of dust, rust, dirt, and other 
foreign matter.

 

• 

Never use a Probe whose insulating protection has been impaired. Such probes 
should be made inoperative by taping the clamp shut in order to prevent operation.  

CS provides a warranty for this product of 12 months covering the material and workmanship 
under the stated operating conditions from the date of delivery. 

Please report any findings immediately and within the warranty time guaranteed by us.  

Excluded from this warranty is damage caused by improper use and non-adherence to the 
instruction manual. 

The warranty is also cancelled once the measuring instrument has been opened provided this 
is not described in the instruction manual for maintenance purposes. This is also the case if the 
serial number has been changed, damaged or removed.  

If in addition to the warranty service necessary repairs, adjustments or similar are carried out, 
the warranty services are free of charge but there is a charge for other services such as trans-
port and packing costs. Other claims, especially those for damage occurring outside the instru-
ment are not included unless responsibility is legally binding. 

CS Instruments (Asia) Co. Ltd. 

 

Room 31, Tower B, Cambridge Plaza 
188 San Wan Road 
Sheung Shui, N.T. 
Hong Kong 
 
Tel:  

+86 (0)755 - 8619 3164

 

Fax:  

+86 (0)755 - 8619 3165

 

email:  

sales@cs-instruments.com.hk

 

website: 

www.cs-instruments.com.hk

 

Warranty 

CS 

In

stru

me

nt

s (A

sia

) C

o.

,  L

td

.

Summary of Contents for 0554 0504

Page 1: ...heck surface of the Probe jaws these should be free of dust rust dirt and other foreign matter Never use a Probe whose insulating protection has been impaired Such probes should be made inoperative by taping the clamp shut in order to prevent operation CS provides a warranty for this product of 12 months covering the material and workmanship under the stated operating conditions from the date of d...

Page 2: ...0 to 70 35 ºC to 45 ºC 95 ºF to 113 ºF Maximum Conductor Size One 51 mm 2 0 inch Maximum Jaw Opening 52 mm 2 04 inch Dimensions 205 x 97 x 44 mm 8 07 x 3 82 x 1 73 inch Weight 480g 16 9 oz General Specifications Operation Instructions 1 Connect the current sensor to one of DS 300 portable analog input terminals 1 Center the single conductor inside the Probe jaws 2 Make sure the Probe is perpendicu...

Page 3: ...0 to 70 35 ºC to 45 ºC 95 ºF to 113 ºF Maximum Conductor Size One 51 mm 2 0 inch Maximum Jaw Opening 52 mm 2 04 inch Dimensions 205 x 97 x 44 mm 8 07 x 3 82 x 1 73 inch Weight 480g 16 9 oz General Specifications Operation Instructions 1 Connect the current sensor to one of DS 300 portable analog input terminals 1 Center the single conductor inside the Probe jaws 2 Make sure the Probe is perpendicu...

Page 4: ...heck surface of the Probe jaws these should be free of dust rust dirt and other foreign matter Never use a Probe whose insulating protection has been impaired Such probes should be made inoperative by taping the clamp shut in order to prevent operation CS provides a warranty for this product of 12 months covering the material and workmanship under the stated operating conditions from the date of d...

Reviews: