14.  Order information 
 

Description 

Order no. 

DS 300-P2 mobile version with data logger for 1 million measured values including 2 
digital inputs, 

without

 analogue inputs, in a robust case 

0500 3101 

DS 300-P4 mobile version with data logger for 1 million measured values including 2 
digital inputs and 2 analogue inputs, in a robust case 

0500 3225 

DS 300-P6 mobile version with data logger for 1 million measured values including 2 
digital inputs and 4 analogue inputs, in a robust case 

0500 3226 

Consumption sensor VA 400, max. version (185 m/s), length 220 mm including 5 m 
cable and certificate 

0695 0122 

HighSpeed version of consumption sensor (224 m/s) 

Z695 4002 

Sensor length 300 mm 

ZSL 0300 

Sensor length 400 mm 

ZSL 0400 

Special version for oxygen measurement 

3200 0010 

FA 410 dew point sensor, -80…+20 °Ctd incl. mobile meas. chamber and 5 m cable 

0699 0411 

Standard measuring chamber up to 16 bar 

0699 3390 

Measuring chamber for granulate driers for minimum over pressure 

0699 3490 

Precision pressure sensor CS 16 (0…16 bar) accuracy < 0.5 % * 

0694 3555 

Precision pressure sensor CS 40 (0…40 bar) accuracy < 0.5 % * 

0694 3930 

Precision pressure sensor CS 1.6 absolute  (0…1.6 bar absolute) accuracy < 0.5 % * 

0694 3550 

Precision pressure sensor CS 16 (0…16 bar) accuracy < 1 % * 

0694 1886 

Precision pressure sensor CS 40 (0…40 bar) accuracy < 1 % * 

0694 0356 

Precision pressure sensor CS 1.6 absolute (0…1.6 bar absolute) accuracy < 1 % * 

0694 3551 

Clamp-on ammeter 0…1000 A AC incl. 5 m connection cable with ODU plug 

0554 0504 

Screw-in temperature probe Pt100, Class A, length 300 mm, -50…+500 °C * 

0693 0002 

Temperature probe cable Pt100, Class A, length 150 mm 

0604 0102 

Temperature probe cable Pt100, Class A, length 300 mm 

0604 0100 

Clamp screwing 6 mm, G 1/2", PTFE clamping ring, pressure-tight up to 6 bar 

0554 6003 

Clamp screwing 6 mm, G 1/2", VA clamping ring, pressure-tight up to 10 bar 

0554 6004 

Connection cables: 

 

Connection cable for VA/FA Series 400 5 m with ODU plug 

0553.0111 

Connection cable for probes 5 m with ODU plug (for pressure sensors and 
temperature probes) 

0553.0110 

Extension cable 5 m for DS 300 mobile version with ODU plug 

0553.0103 

Software

 

CS Soft Professional, data evaluation in graphic and table form with USB cable 

0554 7010 

CS Analysis Software for leakage and cost calculation including CS Soft Professional 
software 

0599 2011 

Calibration of consumption/dew point sensors: 

 

Dew point: Precision calibration at -40 °Ctd incl. ISO certificate 

0699 3396 

Dew point: Precision calibration at 0°C and 10 °Ctd incl. ISO certificate 

3200 0003 

Consumption: 5-point precision calibration with ISO certificate 

3200 0001 

Real gas calibration 

auf Anfrage 

* Attention: Sensor without any connection cable! Please order connection cable separately. 

Summary of Contents for DS 300 mobile version

Page 1: ...V4_03_2011 Instruction manual D DS S 3 30 00 0 m mo ob bi il le e v ve er rs si io on n Multi channel display and data logger...

Page 2: ...er You have made the right decision by choosing a measuring instrument from CS Instruments GmbH Thousands of customers buy our high standard products every year There are a few good reasons for doing...

Page 3: ...ours Up to 6 parameters can be recorded at the same time consumption pressure dew point current consumption pressure temperature Special features All relevant measured data at a glance Actual air cons...

Page 4: ...charging time 10 hours Display Graphic display 160 x 100 pixels with back light Accuracy Dew point see sensor specifications Consumption see sensor specification Pressure 0 5 F S Current 5 25 A 2 100...

Page 5: ...y instructions Observe measuring ranges of the sensors Observe the admissible storage and transportation temperature as well as the permitted operating temperature e g protect the instrument from dire...

Page 6: ...tting 20 C 1000 hPa All volume flow values m h and consumption values indicated in the display are related to 20 C 1000 hPa according to ISO 1217 intake condition 0 C and 1013 hPa standard cubic meter...

Page 7: ...ange from to Measuring range from to 1 4 6 DN 6 1 0 157 l min 2 0 190 l min 1 2 16 1 DN 15 3 5 1516 l min 6 0 1836 l min 3 4 21 7 DN 20 0 4 178 m h 0 7 215 m h 1 27 3 DN 25 0 6 295 m h 1 1 357 m h 1 1...

Page 8: ...50 bar standard Accuracy 0 5 Ctd 10 to 50 Ctd typical 2 Ctd at 40 Ctd Operation temperature 20 to 70 C Storage temperature 40 to 80 C Screw in thread G1 2 stainless steel 3 measured value per FA 410...

Page 9: ...imum 4 hours without any mains supply In case of plugged in mains supply the rechargeable batteries will be loaded also if the instrument is switched off 1 2 3 Sensor connections factory settings 1 Co...

Page 10: ...10 10 Survey operation menu with Enter one menu level down and return with Back...

Page 11: ...1 USB connection icon This icon shows that DS 300 mobile version is connected to a PC via USB 2 Logger module status icon Logger module status WAIT Time start conditions set waiting for the sart of lo...

Page 12: ...nsor setting System status and setting Item 2 of 5 Back Enter Selectable menu item it shows 4 items at a time If the total items in the current menu level is more than 4 items the menu should scroll o...

Page 13: ...the e key to go back to the last menu level without activating the selected option Item 1 of 2 Back Enter Example Time and date setting 1 Use S and T key to adjust the time 2 Use f key to move from H...

Page 14: ...lly and start to display real time measurement values acquired from those sensors The measurement values may be displayed on more than one page To see another page just press the or button Pipe 1 flow...

Page 15: ...e logging rate is 10 seconds it will calculate an average value out of the last 10 measurement values and store it as a recorded sample Manual start Start stop logging Starts or stops the data recordi...

Page 16: ...can be made Set inner diameter For calculation of volume flow consumption and flow Set total consumption counter Counter can be re set to zero or set to any value Enter volume flow unit Selection of...

Page 17: ...recognized so the analogue sensor for the respective channel has to be selected The analogue inputs are preconfigured ex factory however they can be freely adjusted via the keypad For this purpose the...

Page 18: ...ration software Attention Maximum current supply 12 VDC 25 mA If the non CS analogue sensors have a higher current consumption please use an own power supply Connection cables CS Instruments offers co...

Page 19: ...ses or if the serial number in the instrument has been changed damaged or removed The warranty time for DS 300 is 12 months If no other definitions are given the accessory parts have a warranty time o...

Page 20: ...94 1886 Precision pressure sensor CS 40 0 40 bar accuracy 1 0694 0356 Precision pressure sensor CS 1 6 absolute 0 1 6 bar absolute accuracy 1 0694 3551 Clamp on ammeter 0 1000 A AC incl 5 m connection...

Page 21: ...21 Notes...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Page 24: ...4955 Harrislee Phone 49 0 461 700 2025 Fax 49 0 461 700 2026 info cs instruments com www cs instruments com Sales office South Germany CS Instruments GmbH Zindelsteiner Stra e 15 D 78052 VS Tannheim P...

Reviews: