15
V5-02-2010
Measuring ranges depending from the inner diameter of the pipe
MEASURING RANGES HIGH SPEED
Sensor
VA 400 - high speed version up to 224.0 m/sec.
Inner diameter
of the pipe
Flow
(final value of measuring range)
max.
Inch
mm
m³/h
m³/min
l/min
l/s
m/s
2 1/2"
65.0 2204.93
36.75 36748.79 612.48
224.0
70.3 2588.55
43.14 43142.50 719.04
224.0
71.1 2647.80
44.13 44129.99 735.50
224.0
76.1 3040.63
50.68 50677.24 844.62
224.0
3"
80.0 3364.33
56.07 56072.15 934.54
224.0
82.5 3582.20
59.70 59703.26 995.05
224.0
84.9 3793.65
63.23 63227.43 1053.79 224.0
90.0 4268.24
71.14 71137.32 1185.62 224.0
4"
100.0 5275.76
87.93 87929.41 1465.49 224.0
107.1 6058.78
100.98 100979.72 1683.00
224.0
110.0 6391.34
106.52 106522.31 1775.37
224.0
5"
125.0 8263.17
137.72 137719.57 2295.33
224.0
133.7 9453.44
157.56 157557.27 2625.95
224.0
6"
150.0 11913.22
198.55 198553.68 3309.23
224.0
159.3 13436.25
223.94 223937.58 3732.29
224.0
182.5 17655.97
294.27 294266.18 4904.44
224.0
190.0 19136.96
318.95 318949.42 5315.82
224.0
8"
200.0 21229.73
353.83 353828.78 5897.15
224.0
206.5 22632.08
377.20 377201.39 6286.69
224.0
10"
250.0 33211.03
553.52 553517.21 9225.29
224.0
260.4 36074.61
601.24 601243.50 10020.73
224.0
12"
300.0 47880.89
798.01 798014.80 13300.25
224.0
309.7 51027.24
850.45 850454.04 14174.23
224.0
339.6 61355.72
1022.60 1022595.32 17043.26
224.0
400.0 85121.58
1418.69 1418692.98 23644.88
224.0
500.0 133002.47
2216.71 2216707.78 36945.13
224.0
600.0 191523.55
3192.06 3192059.20 53200.99
224.0
700.0 260684.83
4344.75 4344747.24 72412.45
224.0
800.0 340486.31
5674.77 5674771.91 94579.53
224.0
900.0 430927.99
7182.13 7182133.20 119702.22
224.0
1000.0 532009.87
8866.83 8866831.11 147780.52
224.0
Referred to DIN 1945/ISO 1217 (20 °C, 1000 mbar) and compressed air