Installation / Commissioning
VA 550 Ex / VA570 Ex English
V1.08
Page 6 of 10
3.3
Installation / Commissioning
•
metal parts (housing and fixing material) are to be included in the potential equalization
•
The use of the sensor is only allowed in the permissible temperture range of T4 (135°C) .
•
Only certified cable glands (II 2 G Ex db IIC Gb / II 2 G Ex tb IIIC T90°C Db) are allowed to use.
•
Turning or opening of the housing is allowed to perform only in strainless state and after a
waiting time of > 5 minutes after switching off the sensor.
•
In hazardous areas, the requirements of IEC/EN 60079-14 Section 9 must be observed.
3.4
Name plate
1
Sensortype
2
Ordering No.
3
Serialnumber
4
max. Operatingtemperature oft he sensor, Power supply range, power consumption
5
CE Mark
6
Identification number of notified body
7
Ex mark
8
Year of first certification and report no of notified body report
9
Equipment group and catogory as per directive 2014/34/EU
10
WEEE-mark
11
Notes
12