10
Location
SITE SELECTION
1. Select a site in the building near the center of the pro-
posed, or existing, duct system.
2. Give consideration to the vent system piping when se-
lecting the furnace location. Be sure the venting system
can get from the furnace to the termination with minimal
length and elbows.
3. Locate the furnace near the existing gas piping. Or, if
running a new gas line, locate the furnace to minimize
the length and elbows in the gas piping. See Figure 5.
4. Locate the furnace to maintain proper clearance to
combustibles as shown in following Figure 6.
CLEARANCE – ACCESSIBILITY
The design of forced air furnaces with input ratings as
listed in the tables under Figure 6 are certified by CSA-In-
ternational for the clearances to combustible materials
shown in inches.
See name/rating plate and clearance label for specific
model number and clearance information.
Service clearance of at least 24 inches (61 cm) is recom-
mended in front of all furnaces.
NOTE:
Use recommended 24” (61 cm) clearance if accessi-
bility clearances are greater than fire protection clearances.
For downflow non-zero clearance furnace installations, the
minimum clearance required on the right side of the fur-
nace is shown in Figure 4. If this clearance cannot be
maintained, a downflow zero-clearance kit; RXGY-ZK will
need to be installed.
GENERAL INFORMATION (cont.)
AIR FLOW
NOTE:
HORIZONTAL LEFT ORIENTATION DEPICTED IN ILLUSTRATION.
HORIZONTAL RIGHT ORIENTATION IS SIMILAR IN INSTALLATION.
ST-A1194-05-X0
OPTION - B
2” - 3” PIPE
OPTION - A
2” PIPE
8”
6”
ST-A1194-40-X0
CLEARANCE FLUE VENT TO WALL
!
WARNING
THIS FURNACE IS NOT APPROVED OR RECOM-
MENDED FOR INSTALLATION ON ITS BACK, WITH
ACCESS DOORS FACING UPWARDS.
!
WARNING
DO NOT LIFT THE UNIT BY THE HEAT EXCHANGER
TUBES. DOING SO CAN DAMAGE THE HEAT EX-
CHANGER ASSEMBLY.
!
WARNING
COMBUSTIBLE MATERIAL MUST NOT BE PLACED
ON OR AGAINST THE FURNACE JACKET. THE
AREA AROUND THE FURNACE MUST BE KEPT
CLEAR AND FREE OF ALL COMBUSTIBLE MATERI-
ALS INCLUDING GASOLINE AND OTHER FLAMMA-
BLE VAPORS AND LIQUIDS. PLACEMENT OF
COMBUSTIBLE MATERIALS ON, AGAINST OR
AROUND THE FURNACE JACKET CAN CAUSE AN
EXPLOSION OR FIRE RESULTING IN PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH. THE
HOMEOWNER SHOULD BE CAUTIONED THAT THE
FURNACE AREA MUST NOT BE USED AS A
BROOM CLOSET OR FOR ANY OTHER STORAGE
PURPOSES.
!
WARNING
UPFLOW FURNACES ARE DESIGN- CERTIFIED FOR
INSTALLATION ON COMBUSTIBLE FLOORS. NOTE,
HOWEVER, THAT FURNACES MUST NOT BE IN-
STALLED DIRECTLY ON CARPETING, TILE OR
OTHER COMBUSTIBLE MATERIAL OTHER THAN
WOOD FLOORING. INSTALLATION ON A COM-
BUSTIBLE MATERIAL CAN RESULT IN FIRE, CAUS-
ING PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
LOCATION REQUIREMENTS
6”
8”
NOTE:
These
dimensions refer
to furnace
clearance only.
For required
vent clearances
and supports,
refer to vent
manufacturer’s
instructions.
FIGURE 4
FIGURE 5
NOTE: THESE ILLUSTRATIONS ARE INTENTIONALLY GENERIC.
NOTE:
SOME PARTS OF YOUR FURNACE MAY APPEAR DIFFERENT.
Summary of Contents for 92MSP SERIES
Page 34: ...34 Field Conversions ...
Page 35: ...35 Field Conversions ...
Page 36: ...36 Field Conversions ...
Page 37: ...37 Field Conversions ...
Page 38: ...Field Conversions 38 ...
Page 99: ...99 ...
Page 100: ...100 CM 0716 ...