background image

INSTALL ATION GUIDE

1 AND 2 INCH IC/CHICAGO RATED HOUSING  |  

ACROBAT

STEP 1 - FRAME INSTALL / HORIZONTAL ADJUSTMENT 

SPREAD HANGER BARS TO APPROPRIATE DISTANCE. FASTEN WITH HARDWARE (BY OTHERS) TO PREVENT VERTICAL MOVEMENT OF FIXTURE.

T-BAR

ROUND (DOWNLIGHT) SHOWN.

 

 

FOLLOW SAME STEPS FOR SQUARE

WOOD

1 INCH:

(67 x 67mm)

2     in

8

5

2     x

8

5

2 INCH:

(85 x 85mm)

3     in

8

3

3     x

8

3

3 INCH:

(112 x 112mm)

4     in

8

3

4     x

8

3

4 INCH:

(138 x 138mm)

5     in

8

3

5     x

8

3

1 INCH:

2     in (67mm)

8

5

2 INCH:

3 INCH:

4 INCH:

5     in (138mm)

3     in (85mm)

8

3

4     in (112mm)

8

3

8

3

READ AND FOLLOW ALL SAFETY INSTRUCTION! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION. 

Never connect components under load

Do not touch the yellow surface of the LED as it may

damage the light engine

WARNING: RISK OF ELECTRIC SHOCK

Before installation, servicing, or peforming routine

maintenace disconnect power by turning off the circuit

breakers both to the outlet box and to its associated

wall switch

Installation and service of luminaires should be

performed by a qualified licensed electrician in 

accordance with all local and National Electical Codes

DO NOT install damaged product

Verify that supply voltage is correct by comparing it 

with the luminaire label information

All wiring connections should be capped with UL

approved recognized wire connectors

WARNING: RISK OF INJURY

Allow luminaire to cool before servicing and

performing maintenace

Follow all manufacturer’s warnings and restrictions

for: driver type, mounting locations, replacement and

recycling

Wear safety glasses and gloves when installing,

maintaining or servicing

Avoid direct eye exposure to the light source while it

is on 

Keep combustible material away from luminaire

Do not install insulation within 3” (76mm) of any part

of the luminaire or in a way that may entrap heat

WARNING: RISK OF FIRE

WARNING: RISK OF PRODUCT DAMAGE

Summary of Contents for ACROBAT

Page 1: ...ntenace disconnect power by turning off the circuit breakers both to the outlet box and to its associated wall switch Installation and service of luminaires should be performed by a qualified licensed electrician in accordance with all local and National Electical Codes DO NOT install damaged product Verify that supply voltage is correct by comparing it with the luminaire label information All wir...

Page 2: ...ED HOUSING ACROBAT DOUBLE SIDE ADJUSTMENT OUTSIDE Loose the wing nuts to adjust the height of the housing then tighten STEP 3 MAKE ELECTRICAL CONNECTION Step 3 1 Remove knock out and acess cover Step 3 2 Must cut the cable tie for transport Step 3 3 Make electrical connection ...

Page 3: ...GUIDE 1 AND 2 INCH IC CHICAGO RATED HOUSING ACROBAT STEP 4A CEILING CUTOUT FOR TRIMLESS SEE 4B STEP 4B MUD RING TRIMLESS ONLY ATTACH MUD RING TO CEILING WITH SCREWS COVER MUD RING WITH A THIN LAYER OF FINISH PLASTER ...

Page 4: ...TION AND INSTALL SAFETY HOOK WARNING DO NOT USE AS A HANGING DEVICE DOING SO MAY RESULT IN DAMAGE OR INJURY INSTALLATION GUIDE MODULE ACROBAT Step 2 1 Release the Screws to this level Step 2 2 Locate the tool into the module Step 2 3 Twist and lock the tool ...

Page 5: ... THE MODULE Step 3 1 Step 3 2 Aline the module with the collar 3A Insert the module to the collar Step 3 3 Twist and lock the module clockwise 3B Step 3 4 Tighten the screws to secure the module 3C Step 3 5 Twist and release the tool anticlockwise 3B 3C ...

Page 6: ...rews of Lock for Tilt Step 4 6 Tight two Screws of Lock for Tilt Step 4 2 Insert screwdriver through the first clip Step 4 3 Push the screwdriver to the heat sink Step 4 4 Insert screwdriver through the second clip Step 4 5 Use the Screwdriver and adjust tilt angle Scales on the two side of module 4A ...

Page 7: ...for Rotation Step 5 2 Adjust rotate STEP 5 ROTATION ADJUSTMENT 360 Step 6 1 Locate the lens into the module Step 6 2 Twist and lock the lens STEP 6 INSTALL THE LENS INSTALLATION GUIDE ACROBAT Step 5 3 Tighten the Screw of Lock for Rotation 360º ...

Page 8: ...STEP 1 RELEASE THE REFLECTOR AND FLANGE WARNING TURN OFF THE POWER FIRST MAINTENANCE GUIDE IC HOUSING ACROBAT Twist and release the lens STEP 2 RELEASE THE LENS TRIMLESS WALLWASH ...

Page 9: ...ep 3 2 Insert screwdriver through the first clip Step 3 3 Push the screwdriver to the heat sink Step 3 4 Insert screwdriver through the second clip Step 3 5 Use the Screwdriver and adjust tilt angle to 0 Scales on the two side of module 2A STEP 3 TILT THE MODULE MAINTENANCE GUIDE IC HOUSING ACROBAT ...

Page 10: ... the stop position STEP 4 ROTATE THE MODULE STEP 5 REMOVE THE MODULE Step 4 3 Tighten the Screw of Lock for Rotation MAINTENANCE GUIDE IC HOUSING ACROBAT Step 5 1 Release the Screws of Lock for safety to this level Step 5 2 Twist and unlock the module anticlockwise Step 5 3 Remove the module ...

Page 11: ...Screws of driver plate and take out this two screws STEP 6 RELEASE THE ELECTRICAL CONNECTION AND SAFETY HOOK STEP 7 RELEASE THE SCREWS OF DRIVER PLATE MAINTENANCE GUIDE IC HOUSING ACROBAT Step 7 2 Pull out the driver plate ...

Page 12: ...STEP 8 DRIVER REPLACEMENT STEP 9 PUT THE DRIVER PLATE BACK Step 9 2 Tighten the Screws of driver plate MAINTENANCE GUIDE IC HOUSING ACROBAT Step 9 1 insert the driver plate ...

Page 13: ...10 MAKE ELECTRICAL CONNECTION AND INSTALL SAFETY HOOK WARNING DO NOT USE AS A HANGING DEVICE DOING SO MAY RESULT IN DAMAGE OR INJURY Step 11 1 Release the Screws of Lock for safety to this level Step 11 2 Locate the tool into the module Step 11 3 Twist and lock the tool ...

Page 14: ...HE MODULE Step 12 1 Step 12 2 Aline the module with the collar 3A Insert the module to the collar Step 12 3 Twist and lock the module clockwise 12B Step 12 4 Tighten the screws to secure the module 12C Step 12 5 Twist and release the tool anticlockwise 12B 12C ...

Page 15: ...rews of Lock for Tilt Step 13 6 Tight two Screws of Lock for Tilt Step 13 2 Insert screwdriver through the first clip Step 13 3 Push the screwdriver to the heat sink Step 13 4 Insert screwdriver through the second clip Step 13 5 Use the Screwdriver and adjust tilt angle Scales on the two side of module 13A ...

Page 16: ...G ACROBAT Step 14 1 Release the Screw of Lock for Rotation Step 14 2 Adjust rotate STEP 14 ROTATION ADJUSTMENT 360 Step 15 1 Locate the lens into the module Step 15 2 Twist and lock the lens STEP 15 INSTALL THE LENS Step 14 3 Tighten the Screw of Lock for Rotation 360º ...

Reviews: