CSL CS208-3G INTELLIGENT INTEGRATED READER with GPS
USER'S MANUAL, VERSION 1.0.0
Copyright © Convergence Systems Limited, All Rights Reserved
22
5.3.1
Format of default.ini for initial setting of CS208 RFID reader
[DEVICEID]
Model = CS208
; Model Name
ID = SerialNumber ; Device ID (default set to CS208 Reader internal serial number if the ID =
SerialNumber, you can change it other name)
CommMode = NETWORK ; Communication mode (GPRS / NETWORK / USB / SMS / SERIAL)
[NETWORK]
DHCP = N ; Ethernet DHCP N/Y (N means Static IP)
IP = 192.168.25.208 ; Ethernet IP Address, Static IP
Subnet = 255.255.255.0 ; Ethernet Subnet
Gateway = 192.168.25.1 ; Ethernet Gateway
DNS1 = 192.168.25.1 ; First DNS
DNS2 = 192.168.25.1 ; Second DNS
[GSM]
Antenna = 0
; 0 = Auto select,
1 = Antenna Front Side;
2 = Antenna Back Side,
3 = External Antenna
[GPRS]
APN = CMNET
; GPRS APN (CMNET in China, CMHK in HK, rcomnet in India) (APN
stands for Access Point Name, which is a property unique to a service
provider)
PHONENUMBER = *99# ; Dialup network phone number
[SMS]
PhoneNumber =
; Phone number of Backend control center
AutoSwitchOverTime = 60
; Time of switching to SMS when network connection fails (minute)
AuthorizedSender1 =
; SMS authorized sender 1
AuthorizedSender2 =
; SMS authorized sender 2
AuthorizedSender3 =
; SMS authorized sender 3
AuthorizedUser1 =
AuthorizedUser2 =
AuthorizedUser3 =
AuthorizedPassword1 =
AuthorizedPassword2 =
AuthorizedPassword3 =
[SERVER]
BackendServer = 1 ; Select Backend Server (1/2)
ServerIP1 = 192.168.25.100 ; Backend Server IP 1
ServerIP2 = 192.168.25.108 ; Backend Server IP 2
Port = 9092 ; Backend Server Port number
SynchronizationInterval = 60 ; Keepalive interval time (minute). Reader will send keep alive packet
per this time in minute.
[DATA]
ReadTag = N ; Read Tag at power up or restart
Access Password = 00000000 ; Tag Password
TagAuthenticationMask = ; Authenticated TAG Mask (bit mask 1 = 1, 0 = 0, * = wildcard)
MultiBank1 = NONE
; First additional data bank to be read (Multi bank reading)
Offset1 = 0 ; First additional data Offset
Count1 = 0 ; First additional data length (word)
MultiBank2 = NONE ; Second additional data bank to be read (Multi bank reading)