System Testing (continued)
5. If the quiescent (non-active) states of the input terminals are incorrect, i.e.
‘positive applied/removed is inverted, then the ARC will report that the Alarm/
Restore or Open/Close is the ‘wrong way round’. To correct this, use the
Self Learning Input feature. See Appendix 2.
6. If you are using SMS signalling, check that the relevent message(s) has
been received on the GSM phone(s).
7. If at any time you wish to cancel a call, short the Reset pins. See Fig 1 & 2.
8. If you are using the Alarm Abort feature, set the Alarm Panel, initiate an
alarm condition and (If the alarm system incorporates bell delay this will be
overridden) then unset the alarm system within 90 seconds.
Check that the alarm abort signal has been sent to the ARC and, if selected,
the alarm system has reset.
9. Remember to note the SIM Card number, NVM ‘chip’ number (and any se-
curity access numbers) on the site records that will be stored at your office.
10.Your DualCom is now fully tested.
7