background image

 

CSL

 Safe

 

Electronic Lock

 

CHANNEL

 

SYSTEMS LTD 

 

 

 

 

 

 

 

地址

:

香港九龍新蒲崗大有街

2

號旺景工業大廈七樓

H

 

Add: Flat H. 7/F., Wong King Ind Building, 2 Tai Yau Street, San Po Kong, Kowloon, Hong Kong Tel:

 852- 2699 9001

    Fax: 

852- 2329 

8393

    E-mail: info@channel-sys.com Website: www.channel-sys.com 

 

P. 2 

 

4.User Card (

1pc or 5 pcs

)   

User Card Quantity Confirmation: 1 pc or 5 pcs   

    A.

 

User card 1 pc only:

 after initialization, the default is one user card only. 

   

B

User cards 5 pcs allowed:

 Scan the master card 4 times, then scan the owner card once, after music sound, the user 

cards can be programmed 5 pcs. 

Program User Card:

 (In locked status),

 

Scan the master card near the inductive area, music sound and red & green light 

blink, scan the card again, music sound and green light blinks, scan a Mifare card, music sound and green light blinks 

(and  then  off),  the programmed card  is  User card.  (During  the  green  light  blink period,  some  more  user cards  can be 

programmed until 

maximal

 5 pcs on condition that the function is set in the 5 pcs card status. 

Delete Some  User  Card:

 Scan the  master card, music sound and red & green  light blink, scan the card again,  music 

sound and green light blinks, scan the user card, another music sound and green light blinks (and then off), the user card 

is deleted. (This function seldom used) 

Delete All  User Cards: 

Scan the master card, music sound and red & green lights blink 6 seconds, a beep sound and 

green light on, the lock is unlocked, and the user cards are deleted.

 

User Card Unlocking 

Scan the user card, music sound and green light on, the lock is unlocked. 

User Card Locking

In unlocked status, scan the user card, music sound and red light on, the lock is locked.   

Note: User card is used to unlock or lock. 

After unlocked by the master card, the user card(s) are deleted 

5. Setting of Locking Mode   

A. Auto-locking Mode: 

After unlocked by scaning the user card near the inductive area, the lock is automatically locked 

when the green light change to red light 5 seconds later. 

    Note: the default is in auto-locking mode after the cards program. 

    Setting method: 

Scan the master card on the inductive area, then scan the owner card once, music is sounded, the lock 

changes to auto-locking mode from manual-locking mode.

 

B.

 

Manual-locking Mode:

   

   

Setting method: 

Scan the master card on the inductive area, then scan the owner card once, music is sounded, the lock 

changes to manual-locking mode from auto-locking mode. 

After unlocked by scaning the user card, the lock is in passage (unlocked) status, the lock can be locked by scanning the 

user card again. 

 

Functions: 

Light Indication in Locked Status 

When the lock is in locked status, red light flashes every 6 seconds to indicate the lock in use.   

 

Illegal Card Alarm 

Scan  any  illegal card  6 times, the lock emits alarms 20 seconds. (During the alarm period,  scan the opening card can 

terminate the alarm). 

 

 

 

 

 

 

Reviews: