UniCAN 3 – Installing the device
Installation Manual
7
Version 01.00 // 2018
3.4 Installation
NOTE!
i
Cable shield, housing and ground of the connections are connected directly to the
power supply ground (Power GND, negative pole to ground).
)
Incorrect cabling may cause damage to the device.
)
When connecting the device, ensure correct polarity and supply voltage.
→
Please also observe chapter 3.6.2 “CAN interface”.
NOTE!
i
Trouble-free functioning and electrical safety can only be ensured if the product is
installed properly.
)
Ensure proper installation.
)
The device may only be operated within the working environment specified.
→
See also “UniCAN 3” datasheet.
NOTE!
i
Observe EMC regulations.
)
The device and its antennas must be kept more than 20 cm away from the human
body during operation.
)
For compliance with FCC regulations, the antenna gain may not exceed 2 dB.
i
Information on the current status of device and associated software can be found
in the “readme.txt” file of the CSMuniconf software installation package. The most
current version of CSMuniconf can be found in the download area of the CSM website.
→
See: https://s.csm.de/en-uc
3 4 1 Check before connection
)
Ensure that the cables required for proper connection are used (connection to power supply is
usually made using the K212 cable).
)
Ensure that polarity and supply voltage are correct.
→
See also chapter 3.6.1 “Power supply and Ethernet”.
)
Comply with the specifications for all connected components.
3 4 2 Connecting the device
)
Attach CAN connections of the device to the CAN bus system.
)
Connect device to power supply.
3 4 3 Inserting CF card and SIM card
3.4.3.1
Opening the hinged cover
The hinged cover of the device can be opened as follows:
)
Press against the hinge lightly from
below (see Fig. 3-4).
⇨
The lock is released, the hinged
cover opens.
)
Open the hinged cover fully as
shown in Fig. 3-5.
Fig. 3-4: Releasing the lock
Fig. 3-5: Opening hinged cover