background image

UniCAN 3 – General information

Installation Manual

1

Version 01.00 // 2018

1  General information

1.1  Liability disclaimer

This installation manual and other documents are part of the product and contain important informa-

tion for its safe and efficient use. To maintain the high quality level the product is continuously being 

developed, which may result in the product’s technical details changing at short notice. As a result, the 

contents of this documentation may differ from the technical specifications of the product. No claims 

against the manufacturer can therefore be derived from the contents of the product documentation.
CSM GmbH is not liable for technical or editorial errors or missing information.
CSM GmbH assumes no liability for damage resulting from improper use of the product and/or 

non-observance of the product documentation, in particular the safety instructions.

 

See chapter 2 “Safety instructions”.

1.2  Warranty and exclusion of warranty

The warranty covers the safety and functionality of the product within the warranty period. Excluded 

from the warranty are claims based on possible consequential damages caused by malfunction or 

non-function of the product.
The warranty shall become invalid if:

 

f

the product is handled improperly,

 

f

the product is changed,

 

f

the information in the documentation belonging to the product is not observed,

 

f

the product is operated with accessories or parts which are not explicitly approved for operation 

by the manufacturer of the product.

 

See chapter 2 “Safety instructions”.

1.3  Electromagnetic compatibility (EMC)

The manufacturer declares that UniCAN 3 data loggers are in conformity with the 

requirements of EU Directive 2014/30/EU.

NOTE!

i

To ensure that operation is as trouble-free as possible, appropriately suitable cables 

must be used for connection.

 

)

Use only shielded cables for the serial data line outside metal housings.

 

)

Use only suitable shielded and twisted pair wires for the CAN bus.

Summary of Contents for UniCAN 3

Page 1: ...Innovative Measurement and Data Technology Version 01 00 UniCAN 3 Installation Manual ...

Page 2: ...gative consequences Become familiar with local regulations for separate collection of electrical and electronic equipment Follow local regulations and do not dispose of old equipment with house hold waste Contact information CSM offers support for its products over the entire product life cycle Updates for the individual components e g documentation configuration software and firmware are made ava...

Page 3: ... 2 2 Obligations of the operator 2 3 Installing the device 3 3 1 General information 3 3 2 Connection overview 3 3 3 LED and status indicators 4 3 4 Installation 7 3 4 1 Check before connection 7 3 4 2 Connecting the device 7 3 4 3 Inserting CF card and SIM card 7 3 4 4 Putting device into operation 8 3 5 Replacing the battery 8 3 6 Connectors 9 3 6 1 Power supply and Ethernet 9 3 6 2 CAN interfac...

Page 4: ...ions See chapter 2 Safety instructions 1 2 Warranty and exclusion of warranty The warranty covers the safety and functionality of the product within the warranty period Excluded from the warranty are claims based on possible consequential damages caused by malfunction or non function of the product The warranty shall become invalid if f f the product is handled improperly f f the product is change...

Page 5: ...system can be a danger to life for persons and cause damage to property Read the accompanying technical documentation before putting into operation Observe relevant safety guidelines Only suitable device versions may be connected bus type and protocol Ensure that the measurement configuration is suitable Ensure that the work is only carried out by qualified and trained personnel 2 2 Obligations of...

Page 6: ...02 12 ART1271202 LTE ART1271302 LTE_US included optional not available Tab 3 1 Product versions excerpt A complete UniCAN 3 system consists of the following components f f UniCAN 3 with firmware and CF card as storage medium f f K212 power cable f f CSMuniconf PC software f f K201 splitter cable f f CSMdataconv PC software optional f f K204 DigIO cable f f SIM card optional f f K213 Ethernet adapt...

Page 7: ...tected or no card access orange green blinking Activity card access red continuously lit Error state or firmware update in progress Tab 3 3 Color codes for measurement status LED There is also a 2 digit 7 segment display on the front of the UniCAN 3 This display supplements the two LEDs and is used for visualization of device status and error codes The location of a dot determines which display is...

Page 8: ...erver login 5 6 Error occurred while reading from server 5 7 Error occurred while writing to server 5 8 Checksum error occurred FTP 5 9 Invalid transport configuration 6 0 Resource occupied 6 1 Unspecified connection error 6 2 Error occurred while setting the modem access method 6 3 Non specified download error occurred 6 4 Upload was canceled 6 5 Invalid host definition 9 1 Internal upload task e...

Page 9: ...e 16 CAN bus error detected 17 CAN bus message lost 18 Card FIFO overflow 19 Internal system error occurred Other indications Idle mode no card inserted or detected on Everything OK measurement running no errors detected uF Updating firmware Tab 3 5 Status values for measurement status LED Example In Fig 3 3 the orange green flashing network LED indicates activity A continuously lit green status L...

Page 10: ...dB i Information on the current status of device and associated software can be found in the readme txt file of the CSMuniconf software installation package The most current version of CSMuniconf can be found in the download area of the CSM website See https s csm de en uc 3 4 1 Check before connection Ensure that the cables required for proper connection are used connection to power supply is usu...

Page 11: ...card into a UniCAN 3 make sure that the card holder is inserted into the slot with the SIM card facing upward If the card holder is inserted with the SIM card facing downward the card can fall out of the holder and damage the device 3 4 4 Putting device into operation Switch on the device or connect it to the power supply The start of measurement is indicated by on on the 7 segment display and occ...

Page 12: ...minus 7 31 Power GND Power supply ground Housing Shield Cable shield Tab 3 6 Power supply Ethernet socket pin assignment back view of the device The following table shows the assignment of the signals to the wire colors for a K212 cable LEMO 0B 7 pole to open cable end Signal Description Wire color 30 Power Power supply plus Red 31 Power GND Power supply ground Black 15 Ignition Control signal for...

Page 13: ... 1 11 5 15 6 10 1 CAN1H CAN 1 High 2 CAN2H CAN 2 High 3 CAN3H CAN 3 High 4 CAN4L CAN 4 Low 5 not assigned 6 CAN1L CAN 1 Low 7 CAN2L CAN 2 Low 8 CAN3L CAN 3 Low 9 not assigned 10 CAN4H CAN 4 High 11 CAN1GND CAN 1 Ground 12 CAN2GND CAN 2 Ground 13 CAN3GND CAN 3 Ground 14 CAN4GND CAN 4 Ground 15 not assigned Tab 3 8 Pin assignment of the first left hand 15 pole D SUB HD CAN socket back view of device...

Page 14: ... below 1 V as logical 0 UIN Low low level The input voltage may be within the range of 0 V to 10 above the supply voltage of the battery 1 1 UBatt If the input voltage is less than 3 8 V the impedance is 1 MΩ Otherwise it is 220 kΩ The input voltage level UIN of all digital inputs is determined 1 000 times per second fS 1 kHz A logical 1 of the digital output UOUT High high level corresponds to an...

Page 15: ...rs are available in different versions Not all device versions include a mobile communications modem LTE UMTS EDGE GPRS Activation of the WLAN module and the GNSS module GPS GLONASS BeiDou Galileo is always available as an option Fig 3 8 UniCAN 3 back of housing with antenna connectors Connection for WLAN antenna RP SMA socket Connection for mobile communications antenna FAKRA socket code D bordea...

Page 16: ...respective owners Specifications are subject to change without notice CANopen and CiA are registered community trade marks of CAN in Automation e V EtherCAT is registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany ...