UniCAN 3 – Installing the device
Installation Manual
6
Version 01.00 // 2018
Status values of the status LED
Static errors affecting evaluation of the CF card content
01.
Invalid compact flash card
02. Invalid DFAT-STFS container
03. Invalid REC99 version, incompatible configuration format
04. Invalid firmware version, firmware too old
05. Invalid device option, incorrect device type
06. Invalid transport configuration
07.
Invalid measurement configuration
08. Required license not available
Dynamic errors affecting the measurement currently in progress
15.
Protocol error (e.g. initialization of the ECU not possible)
16.
CAN bus error detected
17.
CAN bus message lost
18.
Card FIFO overflow
19.
Internal system error occurred
Other indications
--.
Idle mode, no card inserted or detected
on. Everything OK (measurement running, no errors detected)
uF.
Updating firmware
Tab. 3-5: Status values for measurement (status LED)
Example
In Fig. 3-3, the orange / green flashing network LED (
③
) indicates activity. A continuously lit green
status LED (
④
) indicates idleness, as a memory card is not inserted.
A push of the button (
②
) activates the status indicator (
①
). “--.” appears as status value of the
measurement (
⑤
) and confirmation of idle mode (see Tab. 3-5). Pressing the button again calls up “4.2”
as status of the transmission (
⑥
), i.e. the data logger attempts to establish a network connection
(see Tab. 3-4).