Carefully remove upwards
Connecting cable
Glass tube
Connecting head
Metal housing
UV-tube with lime converter cartridge
Changing UV-tubes
1. Please first remove the switch panel as described
on page 5. The UV-tube is located under the switch
panel, next to the pump motor.
2. Pull out the UV-tube on the connecting cable and
replace the tube.
3. Reattach the electrical connecting head to the UV-
tube properly and insert it into the glass tube again
with care.
The UV-lamp is to be disposed of in accordance with
legal requirements.
The UV-tube has an operating life of about 5000
hours.
m
Please take care that the quartz glass body
in which the source sits is not damaged
when fitting and removing the UV-source.
All accessories can be retrofitted at any time at the
factory or by an authorised dealer.
m