Technical Data

Noise Information

Measured values determined according to EN 60745.

Typically the A-weighted sound pressure level of the
measuring tool is less than 70 dB(A).

Declaration of Conformity

We declare under our sole responsibility, that the
product described under “Technical data” is in con-
formity with the following standards or standardization
documents: EN 60825-1 according to the provisions
of the directives 2006/95/EC, 2004/108/EC,
98/37/EC (until 28 Dec 2009), 2006/42/EC (from
29 Dec 2009).

Technical file at:
Robert Bosch GmbH, PT/ESC, 
D-70745 Leinfelden-Echterdingen

Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 14.07.2009

Assembly

Inserting/Replacing the Battery 
(see figure A)

Using alkali-manganese or rechargeable batteries is
recommended for operation of the measuring tool.

The measuring tool is provided with batteries inserted.
Before putting into operation for the first time, remove
the safety strip in the battery compartment (“Remove
before Use”).

When the battery low indicator 

14

 lights up, the bat-

teries/rechargeable batteries must be replaced.

To open the battery lid 

22

, loosen screw 

21

 and

remove the battery lid.

When changing the batteries/rechargeable batteries,
pay attention to the correct polarity according to the
representation on the outside of the battery lid.

Replace all batteries/rechargeable batteries at the
same time. Do not use different brands or types of bat-
teries/rechargeable batteries together.

Rotational Laser Level

LM30

Article number

F 034 K61 07B

Plumb beam

z

Point Operation

z

Line Operation

z

Working range (radius) with 
laser receiver, approx.

1)

240 m

Levelling accuracy

1) 2)

– in horizontal position
– in  vertical  position

±

0.2 mm/m

±

0.2 mm/m

Levelling accuracy of the 
spirit level
– in horizontal position
– in  vertical  position

±

8"

±

15"

Rotational speed

150/600 min

-1

Operating temperature

6 ... +49 °C

Relative air humidity, max.

90 %

Laser class

2M

Laser type

635 nm, <1 mW

Laser beam Ø at the exit 
opening, approx.

1)

5 mm

Tripod mount 
(horizontal and vertical)

5/8"

Batteries (alkali-manganese)
Rechargeable batteries

4 x 1.5 V LR14 (C)

4 x 1.2 V HR14 (C)

Operating life time, approx.
– Batteries (alkali-manganese)
– Rechargeable batteries

60 h
48 h

Weight according to 
EPTA-Procedure 01/2003

1.1 kg

Dimensions

130 x 107 x 180 mm

1) at 20 °C

2) alongside the axes

Please observe the article number on the type plate of your 
measuring tool. The trade names of the individual measuring 
tools may vary.

The measuring tool can be clearly identified with the serial 
number 

20

 on the type plate.

Dr. Egbert Schneider
Senior Vice President
Engineering

Dr. Eckerhard Strötgen
Head of Product
Certification

OBJ_BUCH-1045-001.book  Page 6  Wednesday, July 22, 2009  10:40 AM

Summary of Contents for Berger Lasermark Wizard LM30

Page 1: ...en Original instructions Manual Horizontal Vertical Rotary Laser LM30 LM30...

Page 2: ...2 2 610 A12 214 22 7 09 LM30 1 2 10 8 9 6 5 20 7 2 4 5 3 22 19 16 17 18 14 15 13 12 11 21...

Page 3: ...3 2 610 A12 214 22 7 09 23 25 24 26 27 C A B...

Page 4: ...4 2 610 A12 214 22 7 09 29 28 30 31 32 33 34 RC30...

Page 5: ...t supervision They could unintentionally blind other persons or themselves f Do not operate the measuring tool in explo sive environments such as in the presence of flammable liquids gases or dusts Sp...

Page 6: ...he battery low indicator 14 lights up the bat teries rechargeable batteries must be replaced To open the battery lid 22 loosen screw 21 and remove the battery lid When changing the batteries rechargea...

Page 7: ...position Align the measuring tool by turn ing levelling screw 7 so that the air bubble of spirit level 8 for the vertical position is exactly centred Note Precise levelling work is only possible with...

Page 8: ...s is close to the ground the measuring tool should always be mounted on a tripod when measuring dis tances exceeding 20 m If possible also set up the measuring tool in the centre of the work area Apar...

Page 9: ...27 The receiption lense 11 for the remote control is located on the front side of the measuring tool For information on working with the remote control 27 see Remote control page 12 Working with the...

Page 10: ...an at all times Do not immerse the measuring tool in water or other fluids Wipe off debris using a moist and soft cloth Do not use any cleaning agents or solvents Regularly clean the surfaces at the e...

Page 11: ...e Centre Democracy Way Prosperity Park Milnerton Tel 27 021 5 51 25 77 Fax 27 021 5 51 32 23 E Mail bsc zsd co za Bosch Headquarters Midrand Gauteng Tel 27 011 6 51 96 00 Fax 27 011 6 51 98 80 E Mail...

Page 12: ...e remote control for anticlockwise rotation of the rotation head Accessories shown or described are not part of the standard delivery scope of the product A complete overview of accessories can be fou...

Page 13: ...information of the rotational laser level functions see the operating instructions of the rota tional laser level see Rotational Laser Level from page 5 on Rotation Line and Point Operation By pressi...

Page 14: ...Robert Bosch GmbH Power Tools Division 70745 Leinfelden Echterdingen Germany www bosch pt com 2 610 A12 214 2009 07 T 14 XXX...

Reviews: