8
Service and Maintenance
Effective date
30.09.2013
•
Check and clean the linear encoder on the X and Y axis. Clean only the
upper surface of the rubber lips on the linear encoder. If you notice that
the rubber lips are becoming dry or porous, lubricate the surface with
PTFE grease which is supplied with the machine. The protective rubber
lips consist of two layers. If you have to relubricate them, make sure that
they are greased evenly. When lubricating the rubber lips, we recommend
that you first clean the rubber lips with a cloth. Following this, put some
PTFE grease on your fingers and then spread this evenly over the rubber
coating.
Make sure that the grease is never applied too thickly and that it is never
put below rubber coated lips. This could damage the machine.
•
Check the controller cooling fans in the control cabinet. See if they are
dirty and need cleaning. Check the power consumption and temperature
of the power supply. The temperature check is to be carried out manually.
•
Drain the condensate from the compressed air supply filter unit and in-
spect the compressed air system.
•
Clean all of the fans in the PC connected to the machine. Make sure that
the ventilation openings of the PC are open and clear.
•
Motors and gears are maintenance free. Check that the cables and cable
connections are all in a good working condition, and are laid out freely.
•
Perform a functional test on the machine. This includes an inspection of
all limit switches, sensors and all safety protection equipment.
CST GmbH
Königsberger Straße 117
47809 Krefeld - Germany
Page 66 of 69
Betriebsanleitung DLE-AF 01.0 engl.docx