background image

 

“CSUN” is the short name for China Sunergy (Nanjing) Co., Ltd. The 5th digit refers to the cell 

manufacturer, ABC used to represent. And the 6th digit refers to the modules manufacturer 

address, ABC used to represent. The 7th digit refers to the modules production month. ABC 

used to represent. For example, “A” refers to “January”

  “L” refers to “December”

The 8th 

and 9 th digit refer to the modules production workshop. “1” refers to the 1 workshop. The 10th 

to 11th digit refer to the modules production year. “10” refers to the year of “2010”. The last 

five digits refer to serial number from 00001 to 99999.   

 

There are three barcodes on one module. One is permanently attached to the interior of the module 

visible when viewing from the front of the module. This barcode is inserted at the beginning of 

laminating. One is attached to the aluminum frame. And another is attached near the nameplate. 

z

 

Do not remove the label. If you remove the label, the product warranty will be not guaranteed 

by CSUN. 

z

 

The modules would be named only by “CSUN***-**M/P”, They 

are all identical 

products(design, materials, production process, etc ). 

 

3

Mechanical Installation 

Selecting the location 

z

 

In most applications, PV modules should be installed in a location where they will receive 

maximum sunlight throughout the year. In the Northern Hemisphere, the modules should 

typically face south, and in the Southern Hemisphere, the modules should typically face north. 

Modules facing 30 degrees away from true South (or north) will lose approximately 10 to 15 

percent of their power output. If the module faces 60 degrees away from true South (or North), 

the power loss will be 20 to 30 percent.   

z

 

For detailed information on the best elevation tilt angle for the installation, refer to standard 

solar photovoltaic installation guides or a reputable solar installer or systems integrator. 

z

 

The module should not be shaded at any time of the day. 

Summary of Contents for CSUN195-72M

Page 1: ...Jiangning Economic Technical development Zone Nanjing China 211100 Tel 86 25 5276 6728 5809 6530 E mail customer_service chinasunergy com Web http www chinasunergy com IEC Installation Guide For CSUN...

Page 2: ...ic system 2 Product Identification 3 Installation and Operation Selecting the location Selecting the proper support frame Roof mount Pole mount Grounding General installation 4 Wiring and Connection 5...

Page 3: ...lar photovoltaic systems may require specialized skills and knowledge Installation should be performed only by qualified persons z Each module comes with a permanently attached junction box CSUN can p...

Page 4: ...idual module currents z When series connection the maximum total number of series modules shouldn t exceed N N is the number of series modules N Maximum system voltage Voc at standard condition AM1 5...

Page 5: ...5 C 77 F z Under normal outdoor conditions the module will produce current and voltages that are different than those listed in the date sheet Data sheet values are values expected at standard test co...

Page 6: ...is attached near the nameplate z Do not remove the label If you remove the label the product warranty will be not guaranteed by CSUN z The modules would be named only by CSUN M P They are all identica...

Page 7: ...equipment or in locations where flammable gases can be generated or collected Selecting the proper support frame z Always observe the instructions and safety precautions included with the support fram...

Page 8: ...on a roof ensure that the roof construction is suitable In addition any roof penetration required to mount the module must be properly sealed to prevent leaks z In some cases a special support frame m...

Page 9: ...ion to earth using a suitable earth ground electrode z Attach a separate conductor as grounding wire to one of the 6mm diameter grounding holes marked with the grounding symbol on the module frame wit...

Page 10: ...he connection box of the control system and connect the cabled from the PV arrays to the connection box in accordance with the installation indication of the PV control systems z Each module has two 4...

Page 11: ...e Size mm CSUN295 72M 305W 300W 295W 290W 285W 72 M156 156 1956 990 50 CSUN275 72P 290W 285W 280W 275W 270W 265W 72 P156 156 1956 990 50 CSUN245 60M 260W 255W 250W 245W 240W 235W 60 M156 156 1640 990...

Page 12: ...temperature coefficient 0 423 K Series fuse rating A 15 Cells 6 12 pieces monocrystalline solar cells series strings 156mm 156mm Junction box with 6 bypass diodes Cable length 900 mm 1 4 mm 2 Front g...

Page 13: ...75 72P Polycrystalline solar module Type CSUN 290 72P CSUN 285 72P CSUN 280 72P CSUN 275 72P CSUN 270 72P CSUN 265 72P Electrical typical data Pmpp W 290 285 280 275 270 265 Voc V 44 3 44 1 44 0 43 8...

Page 14: ...0 045 K Power temperature coefficient 0 408 K Series fuse rating A 15 Cells 6 12 pieces polycrystalline solar cells series strings 156mm 156mm Junction box with 6 bypass diodes Cable length 900 mm 1...

Page 15: ...45 60M Monocrystalline solar module Type CSUN 260 60M CSUN 255 60M CSUN 250 60M CSUN 245 60M CSUN 240 60M CSUN 235 60M Electrical typical data Pmpp W 260 255 250 245 240 235 Voc V 37 6 37 5 37 3 37 2...

Page 16: ...0 039 K Power temperature coefficient 0 423 K Series fuse rating A 15 Cells 6 10 pieces monocrystalline solar cells series strings 156mm 156mm Junction box with 6 bypass diodes Cable length 900 mm 1 4...

Page 17: ...45 60P CSUN 240 60P CSUN 235 60P CSUN 230 60P CSUN 225 60P CSUN 220 60P Electrical typical data Pmpp W 245 240 235 230 225 220 Voc V 37 1 36 9 36 8 36 7 36 6 36 4 Isc A 8 74 8 67 8 59 8 52 8 40 8 32 V...

Page 18: ...se rating A 15 Cells 6 10 pieces polycrystalline solar cells series strings 156mm 156mm Junction box with 6 bypass diodes Cable length 900 mm 1 4 mm 2 Front glass White toughened safety glass 3 2 mm C...

Page 19: ...onocrystalline solar module Type CSUN 205 72M CSUN 200 72M CSUN 195 72M CSUN 190 72M CSUN 185 72M Electrical typical data Pmpp W 205 200 195 190 185 Voc V 45 6 45 3 45 1 45 0 44 8 Isc A 5 82 5 72 5 63...

Page 20: ...Series fuse rating A 10 Cells 6 12 pieces monocrystalline solar cells series strings 125mm 125mm Junction box with 6 bypass diodes Cable length 900 mm 1 4 mm 2 Front glass White toughened safety glas...

Page 21: ...m AM 1 5 25 C performance deviation of Pmpp 3 performance deviation of Voc V Isc A Vmpp V and Impp A 10 certified in accordance with IEC 61215 IEC 61730 1 2 and UL 1703 0 10 20 30 40 50 0 1 2 3 4 5 6...