Impedo
DUO
User Guide
15
20 minutes power failure ride-through via an internal LiFePO
4
battery.
6.
Data storage
4 GB on-board storage providing data storage of all IEC 61000-4-30
voltage and current values of 10-minute and/or variable trended data
up to the 64
th
harmonic component.
The ImpedoDUO utilise the first in first out principle on default but the
instrument can also be configured to stop when the memory is full. The
instrument can however record more than 6 years of 10 min trended
parameters (including the harmonics and inter-harmonics) and more
than 3 weeks of 3 sec data (harmonics and inter-harmonics).
The use of a SD card for data storage enhances the capability of
the instrument not to lose data, configuration or firmware if
without power for more than 1 year.
7.
Time stamping
GPS time synchronization resulting in a time-stamping certainty better
than 100 ns.
NTP time synchronization as an option.
8.
Communication
Communication is via Ethernet.
Modbus over Ethernet.
DNP3 over Ethernet.
IEC 61850 – optional.
9.
Advanced triggering
User-configurable triggering between different instruments: the
patented Xross-Trigger feature (Described in the Osprey Lite user
manual)
10.
Configuration of instrument
Multi-touch user-interface provides configuration and real-time
information display
; or
Summary of Contents for Impedo DUO
Page 85: ...Impedo DUO User Guide 85 Figure 49 Export harmonic selection...
Page 109: ...Impedo DUO User Guide 109 Appendices 8 Impedo DUO dimensions...
Page 110: ...Impedo DUO User Guide 110 8 1 Panel mounting plates 8 2 19 installation plate...
Page 111: ...Impedo DUO User Guide 111 9 Impedo DUO wiring diagram...
Page 113: ...Impedo DUO User Guide 113 11 Portable ImpedoDUO...
Page 117: ...Impedo DUO User Guide 117 Screw driver USB with meter key Ethernet cable...