Performing Internal Maintenance
Chapter 5: Maintaining and Troubleshooting the RS Monitor
60
PowerStation RS Monitor User Guide
8. Using a small, flat-tipped screwdriver, gently pull back the
white tab next to the top of each bulb and lift the bulb out of
the frame, as shown in the next two illustrations. You can most
easily remove a bulb by gently pulling up on its cable.
Backlight bulb cable
Holes for retracting
backlight bulb cables
Pull back backlight bulb tab
Pull up backlight bulb