Chapter 3: Installing the RS Monitor
Mounting the Monitor in an Enclosure
PowerStation RS Monitor User Guide
21
Mounting the
Monitor in an
Enclosure
You will need to read this section of the manual only if you intend
to mount the RS Monitor in an enclosure. If you plan to mount the
monitor on an adjustable arm, see the documentation that accom-
panies the arm for installation instructions.
This section of the manual will tell you how to mount CTC’s
External AC Power Supply Adapter on the monitor and how to
install the monitor in an enclosure.
Mounting the External
AC Adapter
Since the RS Monitor is a DC device, you will need to use an AC
adapter if you intend to power the monitor with AC voltage. An
External AC Power Supply Adapter (P1X-PWRAC) is available
from CTC, along with an installation kit that will enable you to
mount the adapter either on the back of the monitor or near the
monitor. The adapter can only be mounted on the back of RS
Monitors that do not have a mounting cover.
Important
If you intend to mount the External AC Adapter on the back
of the RS Monitor, be sure to take the adapter’s dimensions
into account when planning the depth of the monitor enclo-
sure.
To mount the External AC Adapter on the back of the
monitor, follow these steps:
1. Place the monitor face-down on a static dissipative mat in a
location free from dirt and moisture and protected against
static discharge.
2. Place the External AC Adapter between the four mounting
holes in the center of the monitor back, as shown below. Make
sure that the Adapter’s DC connection is toward the top of the
monitor and that the AC connection is toward the bottom.
AC connection
Mounting holes
DC connection
AC adapter