18
CTC EcoFlex
End user information
3. Detailed menu description
Settings
►
Lang.
English
Heat pump
No
Indoor sens
No
Boiler pellet °C
80
Alarm FlueGas °C
240
El Boiler °C
50
El boiler max kW
6,0
Max fuse A
20
External control
NR
Setting house Param
Setting pellet
Holiday off
Set. tank
Setting DHW
Save setting
Load setting
Load factory setting
Service
►
Functiontest pellets
Funktionstest other
Alarm info
Functiontest pellet
►
Auger Feeder
Off
Fan %
0
Auger burner %
0
El ignition
Off
Funct. test other
►
ElRelay 1,5/3 kW
0
ElRelay 3/6 kW
0
Pellet Off
Heatingcirpump.
Off
MixingValve Close
DHW pump
Off
Diode sensor
Off
Alarm stored
Last alarm
xxxxx
Stored alarm
xxxxx
xxxxx
xxxxx
xxxxx
Setting Heating
►
Max Primfl °C
55
Min Primfl °C
Off
Heating off
16
Heat curve
Inclination 50
Adjustment 0
Setting pellet
►
Level sensor %
0(50)
Flame detector %
99(50)
Burner type kW
15
Power full auger %
68
Power full fan %
40
Power part auger %
41
Power part fan %
20
Power min auger %
0
Power min fan %
0
Holding min
60
Auger Feeder s
30
Sequenz code
0
Time setting
Day
Thursday
Time
18:03
Stored oper data
Total operation h
8768
El heat kWh
1234
Pellet h
3456
Max prim °C
62
Cold starts
14
Warm starts
354
Night reduction
►
Activated
No/Yes
Type WeekProg
Indoor temp red °C
-2
Prim red °C
-5
WeekProgram
Installer
►
Settings
Service
Operation data
Outdoor °C
-5
Indoor °C
20(20)
Boiler °C
70
FlueGas °C
160
Primfl . °C
45(45)
▼
Operation data
▲
Current A
12(20)
Pellet startphase
1K
Mixingvalve close
Program ID
xxxxxxx
Program date
xx-xx-xx
Operation data
▲
Heatingcirc. pump
On
Elpower 3,0
▼
With indoor sensor
Without indoor sensor
With indoor sensor
Without indoor sensor
EcoFlex
Thurs 8:03
Indoor °C
20.0(20.0)
Indoor Temp
NR
Boiler °C
50
►
Operation data
Stored oper data
Night reduction
Installer
Indoor temp
-
●
●
●
●
+ (52)
Set. tank
►
Charge tank
Yes
Temp tank °C
70
Diff °C
5
Tank prio
No
3.2
Main menu/Normal display menu
This menu is the system’s “basic menu”. The system returns to this menu if
no buttons are pressed within a 10 minute period. All other menus can be
accessed from this menu.
EcoFlex
Mon 15:43
Displays selected product, day and time. Day and time can be set by
selecting this row.
Indoor °C
20,0 (20,0)
Displays current room temperature. The set temperature is displayed in
brackets. Select this row to change set temperature.
Can be set in the range 0.0 … 35.0 °C.
Indoor temp
NR
If an indoor sensor has not been fitted, temperature is adjusted using the
outdoor temperature. Select this row to adjust the temperature supplied to
radiators, see the “Indoor temperature” menu below. If “NR=“ is displayed,
night reduction is in progress.
Boiler°C
80
Boiler water temperature is displayed here. Only display.
Operation data
Select this menu to view all current product operating data, all current tem-
peratures, which components are active etc.
Stored oper data
Select this menu to view the operating data which has been stored over a
longer time period.
3.1
Factory set values
The product is supplied with a set of values, set by the factory, which are
suitable for a normal house with a normal radiator system. These values can
be changed as required. House parameters should in particular be checked.
Ask your installation engineer to determine the correct values.
The following basic values are set by the factory:
Night reduction
Off (constant normal temperature)
Room sensor:
No
Boiler pellets:
80°C
Alarm smoke gas:
240 °C
Electric boiler
50 °C (only Swedish version)
Electric boiler max kW:
6 (only Swedish version)
Main fuse:
20A (only Swedish version)
Burner type:
15 kW
House parameters:
Inclination = 50 Adjustment = 0
Summary of Contents for ecoflex
Page 2: ......
Page 53: ...53 CTC EcoFlex Installation 13 Electric diagram 230V 1N ...
Page 54: ...54 CTC EcoFlex Installation 14 Electric diagram 400V 3N ...
Page 56: ...56 CTC EcoFlex Installation Declaration of Conformity ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...