24
CTC EcoFlex
End user information
Main fuse A
20
I. The house’s main fuse size is set here. Together with a fitted current
sensor, the fuses are protected when using equipment which provides
temporary power peaks, for example cooker, oven, engine heater etc.
where the product temporarily reduces connected electrical power output.
(Only Swedish version)
External control
NR
I. Selection of remote control type. NR= remote controlled night reduction,
for example via the minicall system. SO = power supplier control.
Disconnection of immersion heater for specific periods of time, controlled by
the electricity power supplier (special equipment is required).
Setting house
I/U. When this is selected, a sub menu will be displayed in which the
house’s temperature Param requirement (heating curve) is set, see the
“Setting heating” menu.
Setting pellet
I/U. This selection leads you to a sub menu for pellet burner settings, see
menu Set pellet burner.
Holiday
Off
U. Where you require constant night time lowering of temperatures (for
example when on holiday), the number of days (holiday) can be set here. Up
to 250 days can be set. Off = not activated.
Set.tank
I/U. This option takes you to a submenu for tank settings; see Tank Setting
Menu.
Indoor temp red
°C -2
U. If the holiday function is activated, the number of degrees the
temperature is to be lowered is set here. If a room sensor is not selected,
the number of degrees the radiator prime flow temperature is to be lowered
is set instead.
Save setting
I/U. Your own settings can be saved here. Confirm using the “OK” button.
Load setting
I/U. Saved settings can be retrieved here. Can be useful if you test new
settings, which are subsequently shown to not be satisfactory and want to
restore the old settings.
Load factory setting
I/U. The product is supplied with factory settings. These can be restored by
using this function. Confirm using “OK”. Language, product and product
size are however not reset.
Summary of Contents for ecoflex
Page 2: ......
Page 53: ...53 CTC EcoFlex Installation 13 Electric diagram 230V 1N ...
Page 54: ...54 CTC EcoFlex Installation 14 Electric diagram 400V 3N ...
Page 56: ...56 CTC EcoFlex Installation Declaration of Conformity ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...