28
CTC EcoFlex
End user information
Fan %
0
Pellet burner fan can be activated here. Adjustable 0–100%. Stepless
speed regulation.
Auger burner %
0
The pellet burner auger can be activated here. Adjustable 0–100%. 100%
means that the augers run continuously. A lower per cent means they are
sometimes stationary and sometimes run.
El. ignition
Off
Electric ignition can be activated here.
!
Is only to be activated when the fan is in
operation.
Settings
►
Lang.
English
Heat pump
No
Indoor sens
No
Boiler pellet °C
80
Alarm FlueGas °C
240
El Boiler °C
50
El boiler max kW
6,0
Max fuse A
20
External control
NR
Setting house Param
Setting pellet
Holiday off
Set. tank
Setting DHW
Save setting
Load setting
Load factory setting
Service
►
Functiontest pellets
Funktionstest other
Alarm info
Functiontest pellet
►
Auger Feeder
Off
Fan %
0
Auger burner %
0
El ignition
Off
Funct. test other
►
ElRelay 1,5/3 kW
0
ElRelay 3/6 kW
0
Pellet Off
Heatingcirpump.
Off
MixingValve Close
DHW pump
Off
Diode sensor
Off
Alarm stored
Last alarm
xxxxx
Stored alarm
xxxxx
xxxxx
xxxxx
xxxxx
Setting Heating
►
Max Primfl °C
55
Min Primfl °C
Off
Heating off
16
Heat curve
Inclination 50
Adjustment 0
Setting pellet
►
Level sensor %
0(50)
Flame detector %
99(50)
Burner type kW
15
Power full auger %
68
Power full fan %
40
Power part auger %
41
Power part fan %
20
Power min auger %
0
Power min fan %
0
Holding min
60
Auger Feeder s
30
Sequenz code
0
Time setting
Day
Thursday
Time
18:03
Stored oper data
Total operation h
8768
El heat kWh
1234
Pellet h
3456
Max prim °C
62
Cold starts
14
Warm starts
354
Night reduction
►
Activated
No/Yes
Type WeekProg
Indoor temp red °C
-2
Prim red °C
-5
WeekProgram
Installer
►
Settings
Service
Operation data
Outdoor °C
-5
Indoor °C
20(20)
Boiler °C
70
FlueGas °C
160
Primfl . °C
45(45)
▼
Operation data
▲
Current A
12(20)
Pellet startphase
1K
Mixingvalve close
Program ID
xxxxxxx
Program date
xx-xx-xx
Operation data
▲
Heatingcirc. pump
On
Elpower 3,0
▼
With indoor sensor
Without indoor sensor
With indoor sensor
Without indoor sensor
EcoFlex
Thurs 8:03
Indoor °C
20.0(20.0)
Indoor Temp
NR
Boiler °C
50
►
Operation data
Stored oper data
Night reduction
Installer
Indoor temp
-
●
●
●
●
+ (52)
Set. tank
►
Charge tank
Yes
Temp tank °C
70
Diff °C
5
Tank prio
No
3.17 Menu Function test other
(Installer/Service/Function test)
This menu is used to test the product component function. It is therefore
used by qualified service personnel. All product functions stop when
the menu is activated. Each component can then be tested separately
or together.All control functions are shut off, the only protection against
incorrect operation is the safety limit thermostat of the boiler.
If no button is pressed within a 10 minute period, the product automatically
returns to normal operation. The exception is in menu Pellets in the menu
Function test. This function does not reset automatically.
ElRelay 1,5/3kW
0
Immersion heater 3kW semi activated. First relay 1a (1.5kW), then relay 1b
(3kW). Connected power is displayed.
(Only Swedish version.)
ElRelay 3/6kW
0
Immersion heater 6kW semi activated. First relay 2a (3kW), then relay 2b
(6kW). Connected power is displayed.
(Only Swedish version.)
Summary of Contents for ecoflex
Page 2: ......
Page 53: ...53 CTC EcoFlex Installation 13 Electric diagram 230V 1N ...
Page 54: ...54 CTC EcoFlex Installation 14 Electric diagram 400V 3N ...
Page 56: ...56 CTC EcoFlex Installation Declaration of Conformity ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...