37
CTC EcoFlex
End user information
Alarm
Flue gas 300 °C
Fault:
Flue gas temperature exceed 300 °C.
Action:
Check that the flue gas damper is correctly fitted, clean the boiler.
If the alarm recurs, contact the installation engineer.
Alarm
Safety limit thermostat
Fault:
The safety limit thermostat has triggered.
Action:
Reset by pressing the centre button under the cover casing. If the alarm
recurs, contact the installation engineer.
Alarm texts (Pellet burner)
Alarm
Pellet missing
Fault:
The burner has requested fuel but not received any.
Check:
That there are pellets in the external fuel storage.
Action :
Fill pellets.
Check:
That the filling tube does not have a too shallow slope.
Action:
Shake the tube and change the angle so that pellets do not clog in the
tube.
Check:
That the feed auger angle is not too steep or flow has stopped due to
bridging in the external fuel storage
Action:
Set the feed auger at a shallower angle and turn it forwards and backwards
a few times to loosen bridges. The inlet opening should be in the middle of
the external fuel storage (applies to smaller weekly storage).
Check:
That the external feed auger drive motor is functioning and that the motor
shaft drives the auger helix around.
Action:
If the motor does not run, check this by dismantling it from the auger motor
shaft. Then disconnect the incoming power cable from the boiler and
connect directly to a wall power point using the supplied adapter cable. If
the motor has overheated due to blocking, the motor’s thermal protection
can have been trigged. The motor will not start before it has cooled. Do not
forget to check whether the auger helix is blocked. If it is, unblock by hand
using suitable measures.
Call a service technician if there is a fault on the motor.
Summary of Contents for ecoflex
Page 2: ......
Page 53: ...53 CTC EcoFlex Installation 13 Electric diagram 230V 1N ...
Page 54: ...54 CTC EcoFlex Installation 14 Electric diagram 400V 3N ...
Page 56: ...56 CTC EcoFlex Installation Declaration of Conformity ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...