52
CTC EcoLogic M/L
4.9
Settings
Settings can be made here for, among other things, the
house’s heating and cooling needs. It is important that
the basic heating setting is right for your home. Values
which are set incorrectly may mean that your property is
not warm enough or that an unnecessarily large amount
of energy is being used to heat your property.
4.9.1
Settings Heating circuit 1-*
Max primary fl ow °C
55 (30...80)
Maximum permitted temperature supplied to the
respective heating circuit.
Min primary fl ow °C
Off (Off/15...65)
Minimum permitted temperature supplied to the
respective heating circuit.
Heating, mode
Auto (Auto/On/Off)
Switching between heating season and summer mode
can take place automatically (Auto) or a selection can be
made here to set the heating to "On" or "Off".
•
Auto
= switching the heating season On and Off
carried out automatically.
•
On
= Continuous heating season, the radiator
pump circulates constantly.
•
Off
= there is no heating, the radiator pump does
not run (is turned over).
Heating mode, ext.
Auto/On/Off
The heat mode selected in this menu can be enabled/
disabled externally.
This menu bar is displayed for the current heating circuit
if a remote control input or a weekly schedule has been
defi ned for the function.
Read more in the "Def. Remote Control" section of the
"Installer / Defi ne” chapter.
*The number of possible heating circuits or heat pumps
that can be connected to the system varies depending
on the control system.
Part of the "Installer/Settings/Heating Circuit/Heating Circuit 1"
menu.