FRM220 Chassis Quick Installation Guide
7
FRM220-CH01 Single Slot Stand-alone Chassis
The FRM220-CH01 is designed for tabletop or bench installation. A card slides into the chassis for
a complete, assembled, stand-alone unit. AC power is supplied to FRM220-CH01 through an external
switching AC adapter. (12VDC at 1A)
Installation
Remove the card carefully from packaging after first touching a grounded object, to remove static
charge from your body. Hold the card by the metal face plate and NEVER touch any components on
the board. Align the card with the slots of the CH01 chassis and slide the card all the way in. The DC
power jack will be flush with the rear of the chassis. Use the thumb screw to secure the card,
tightening it only hand tight.
Figure: CH01 Installation
The grounding terminal accepts a 3mm screw (not included). As no ground is provided by the AC
power adapter, connecting an Earth ground to the chassis will provide safety from shock, surge
protection, and through shielding, will reduce both the device's emissions and susceptibility to other
devices' emissions.
Wall Mounting
FRM220-CH01 standalone chassis has the option of adding wall mount capability. One wall mount
kit is required for installing a single standalone chassis on the wall. Each wall mount kit provides a wall
mounting bracket and the screws to attach the bracket to the CH01 chassis. Screws to attach to a wall
are not included.
Use the bracket as a template for drilling holes in a wall and attaching screws. Screws should be
chosen that allow the screw head to pass through the hole in the bracket. The screws in the wall
should be screwed in leaving just enough space so the bracket and CH01 can be hung securely.
Figure: CH01 with Wall Mount Bracket
Operation & Storage Temperature :
- Operating Temperature -- -10°C
– 60°C
- Storage Temperature -- -20°C
– 70°C
- Humidity -- 10
– 90%
Dimension and Weight: ( W x D x H ) mm
- 88 × 141 × 23 mm
- 358g
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
CE NOTICE
Marking by the symbol CE indicates compliance of this equipment to the EMC directive of the
European Community. Such marking is indicative that this equipment meets or exceeds the following
technical standards: EN 55022:1994/A1:1995/A2:1997 Class A and EN61000-3-2:1995, EN61000-3-
3:1995 and EN50082-1:1997
Grounding
Terminal