background image

 

  M N X 1 0 0 0 1 ,  

R E V  

C  

  2 / 8 / 2 0 1 2  

1  

 

Connection Technology Center, Inc. 

 7939 Rae Boulevard 

 Victor, NY 14564 

 (585) 924-5900 

 

 

 

SC901 Series 

Hazardous Area, Factory Set Vibration Signal Conditioners 

Summary of Contents for Pro SC901 Series

Page 1: ...M N X 1 0 0 0 1 R E V C 2 8 2 0 1 2 1 ConnectionTechnologyCenter Inc 7939RaeBoulevard Victor NY14564 585 924 5900 SC901 Series Hazardous Area Factory Set Vibration Signal Conditioners...

Page 2: ...W 4 Introduction 4 Product Selection Guide 5 Specifications 6 Environmental 6 Electrical 6 Physical 6 SECTION 2 INSTALLATION 7 Description 7 Mounting Instructions 8 Electrical Connections 8 SECTION 3...

Page 3: ...S M N X 1 0 0 0 1 R E V C 2 8 2 0 1 2 3 ConnectionTechnologyCenter Inc 7939RaeBoulevard Victor NY14564 585 924 5900 Figure 1 SC901 Series Selection Guide 4 Figure 2 Mounting Dimensions 8 Figure 3 Fro...

Page 4: ...ument contains information on the operation installation and maintenance of the SC901 Series Signal conditioner for Hazardous Areas The SC901 Series signal conditioner accepts input from an accelerome...

Page 5: ...range 0 95 Relative Non Condensing Electrical Power 20 32 VDC unregulated 8 pole low pass and high pass Filter Filter roll off is better than 42 dB octave Accepts mV Input Filters the signal Normaliz...

Page 6: ...l connectors WAGO 237 series positive force terminal blocks for the signal output and sensor input There is also a green indicator light Sensor OK which illuminates when the transducer is properly con...

Page 7: ...nsions Electrical Connections 1 Connect the 24 VDC input power to the two connectors 24 VDC INPUT on the top front of the signal conditioner 2 Connect the cables from the transducer to the SENSOR INPU...

Page 8: ...tor NY14564 585 924 5900 SIGNAL OUTPUT is an unfiltered connection showing the raw signal from the transducer BNC SIGNAL OUT serves the same function as the SIGNAL OUTPUT connection ANALOG OUTPUT is t...

Page 9: ...upplies constant current power turn the power supply off in the data collector prior to collecting data Analog Output Zero Adjustment This section contains test setup and procedures for adjusting the...

Page 10: ...onnectionTechnologyCenter Inc 7939RaeBoulevard Victor NY14564 585 924 5900 Common Problems Blinking green sensor OK light indicates that sensor is not attached Check sensor and cable connections Note...

Page 11: ...required Basic visual checks to ensure integrity should be made periodically General There are no customer replaceable parts The product has been designed for trouble free service under normal operati...

Reviews: