S E C T I O N 2 : I N S T A L L A T I O N
M N X 1 0 0 0 1 , R E V C
●
2 / 8 / 2 0 1 2
7
Connection Technology Center, Inc.
●
7939 Rae Boulevard
●
Victor, NY 14564
●
(585) 924-5900
Mounting Instructions
The conditioner case is designed for quick mounting to a 35mm din rail. The
case can be surface mounted via optional mounting feet.
Figure 2 - Mounting Dimensions
Electrical Connections
1.
Connect the 24 VDC input power to the two connectors (24 VDC INPUT±)
on the top front of the signal conditioner.
2.
Connect the cables from the transducer to the SENSOR INPUT ±
connectors at the bottom front of the signal conditioner. If power and
transducer are connected correctly, the green XDCR OK light will go on.
3.
Connect the desired vibration monitoring test equipment to either the
*SIGNAL OUTPUT ± connector, *BNC SIGNAL OUT connector, or *ANALOG
OUTPUT ± connector.
0.186
TYP
2.375
1.975
0.226
TYP
1.375