Aerial work platform
ZED 20.3 HV
3
COD. UM0284_GB | REV. 0.0 | ED: 09/17
Chapter 8
GB
MAINTENANCE
8.3
Maintenance summary table
CAUTiOn
in order for the warranty to remain valid, inspection and maintenance must be
carried out at an authorised CTE service centre after the irst 100 hours and after
every 1000 hours (or every year) of operation.
8.3.1
Pre-start checks
Description of operation
Section
Visual inspection
O
6.3.1
Check use and maintenance manual
O
6.3.1
Legibility of plates and adhesives
O
6.3.1
Checking for damages and missing, loose or detached parts
O
6.3.1
Check welds, pins and joints
O
6.3.1
Check for any oil leaks
O
8.6
Check pressures
O
8.6.3
Hydraulic oil level check
O
8.6.5
Check hydraulic oil ilter clogging indicators
O
8.6.6
Check the operation of the controls in the platform and on the ground
O
8.7.1
Check safety devices (Emergency Stop)
O
8.7.1
Test limit switches
O
8.7.2
Test power supply differential circuit breaker in the platform.
O
15.3
O
= to be done by an operator
M
= to be done by a qualiied technician
8.3.2
Every 50 hours of operation
Description of operation
Section
Visual inspection
O
6.3.1
Check use and maintenance manual
O
6.3.1
Legibility of plates and adhesives
O
6.3.1
Checking for damages and missing, loose or detached parts
O
6.3.1
Check welds, pins and joints
O
6.3.1
Check for any oil leaks
O
8.6
Check pressures
O
8.6.3
Hydraulic oil level check
O
8.6.5
Check hydraulic oil ilter clogging indicators
O
8.6.6
Check the operation of the controls in the platform and on the ground
O
8.7.1
Check safety devices (Emergency Stop)
O
8.7.1
Test limit switches
O
8.7.2
Test power supply differential circuit breaker in the platform.
O
15.3
Lubrication and greasing
O
8.5
O
= to be done by an operator
M
= to be done by a qualiied technician