12
The Managed Switch can be mounted in an EIA standard-sized, 19-inch rack,
which can be placed in a wiring closet with other equipment. Rack mounting
brackets are provided to mount the Switch.
Procedure
1. Plan the rack position.
2.
Attach the mounting bracket on the switch’s side panels (one on each
side) and secure them with the screws provided.
3. Align the Switch with mounting bracket into the selected mounting rail
position.
4. Then, use the screws provided with the equipment rack to mount the
switch into the selected mounting rails position carefully and firmly.
5. Please ensure that the ventilation holes are not blocked.
2.4 Power ON
The Managed Switch can be used with AC power supply 100-240 VAC, 50
– 60
Hz or DC power supply 48V. The power switch is located at the rear of the unit
adjacent to the power connector.
After the Managed Switch is turned on, the Power LED indicators should light in
green and the FAN should spin.