Series 4 Module User Guide—North America 

| Page 15 of 17 

 

 
 

 

9

 

Notice 

 

 

Changes to certain components of the module are common as Chosen Techno Solar Private Limited continuously strives for 
product improvements. Changes may be a result of component improvements or changes by a supplier, or by minor design 
modifications initiated by First Solar. All products within the same model classification remain functionally equivalent and 
fully  compatible  with  one  another,  even  though  there  may  be  slight  differences,  provided  appropriate  system  design 
practices are employed. 

 

Modifications that do not impact the functionality of the product will typically be made without customer notification. 
Internal testing, and review or retesting by a certifying agency, will be completed before component or design changes are 
introduced into the manufacturing process. 

 

Chosen Techno Solar Private Limited reserves the right to make changes in solar module design and/or specifications at any 
time  without  notice.  Accordingly,  the  reader  is  cautioned  to  verify  that  data  sheets  are  current  before  placing  orders  or 
finalizing system permitting and/or design. Information furnished by  Chosen Techno Solar Private Limited is believed to be 
accurate and reliable. However, no responsibility is assumed by Chosen Techno Solar Private Limited or its subsidiaries for its 
use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted 
by implication or otherwise under any patent or patent rights of Chosen Techno Solar Private Limited or its subsidiaries. 

 

In the event of a conflict between this module User Guide and the instructions of one of the system component 
manufacturers, the system component instructions should prevail. 

 

For information regarding Chosen Techno Solar Private Limited and its products, please visit www.firstsolar.com. For technical 
support, please contact technicalsupport@ctsonesolution.com. 

 

Global 

 

Chosen Techno Solar Private Limited, Inc. 

 

P.O. Box 730 

 

Toledo, OH USA 43697-0730 

  

Web: 

www.ctsonesolution.com 

 

Email:  info@ctsonesolution.com 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PD-5-200-04 NA | REV 3.1 | 0348_UG_NA_11JUL17 

Chosen Techno Solar Private Limited 

Summary of Contents for FS-4100

Page 1: ...User Guide User Guide Chosen Techno Solar Private Limited Series 4 Module North America REV 3 1 PD 5 200 04 NA 0348_UG_NA_11JUL17...

Page 2: ...1 System Derating Factors 5 4 Installation 6 4 1 Mounting 6 4 2 Module Orientation 8 4 3 Module Shading Considerations 8 4 4 Electrical Interconnection 9 5 Mechanical Specifications Drawings 12 6 Prop...

Page 3: ...lers and maintenance personnel Read this User Guide thoroughly before beginning any work related to the installation operation or maintenance of the Chosen Techno Solar Private Limited Series 4 or Ser...

Page 4: ...Chosen Techno Solar Private Limited module reverse current overload may result in module failure including module breakage Extreme and continuous reverse current overload conditions may cause a fire...

Page 5: ...ized or Listed by Underwriters Laboratories UL for their intended purpose Ensure the PV array open circuit voltage does not exceed 1500VDC 1000VDC for UL Canada Install modules with mounting systems t...

Page 6: ...2 FS 4105 2 FS 4107 2 FS 4110 2 FS 4112 2 FS 4100A 2 FS 4102A 2 FS 4105A 2 FS 4107A 2 FS 4110A 2 FS 4112A 2 Nominal Power 5 PMPP W 100 0 102 5 105 0 107 5 110 0 112 5 Voltage at PMA X VMPP V 66 2 67...

Page 7: ...tage VSYS V 1500 2 Maximum Series Fuse ICF A 4 0 1 As received and stabilized ratings at Standard Test Condition 1000W m2 AM 1 5 25 C Cell Temperature 10 2 1000V Listed for UL Canada 3 Measurement unc...

Page 8: ...d using approved hardware in the manner specified by the mounting instructions in Chosen Techno Solar Private Limited Application Note PD 5 320 04 NA Additional mounting systems may be approved for us...

Page 9: ...eight is 3 25 in 82 55 mm Modules used in UL Listed rooftop applications must be installed with approved mounting systems If alternate mounting means are employed this may affect the Listing fire clas...

Page 10: ...from diffuse shading for objects greater than 2 meters or 7 feet There is a low risk of module damage due to shading from walking or standing in front of operating modules or from parking or driving...

Page 11: ...lead wires tight at any time After installation the connected wire must not be under stress or tension Do not use junction box assembly or lead wire strain relief loops to secure excess wire or to be...

Page 12: ...re inverter ratings are appropriate When connecting Chosen Techno Solar Private Limited Series 4 and or Series 4A Modules in a series string ensure that the system design voltage and inverter design s...

Page 13: ...unded ungrounded floating and bi polar system architectures provided all appropriate design requirements are met and approved by First Solar FS Series PV Modules should not be used in positive grounde...

Page 14: ...on Span2 1314 mm 51 73 in Weight 12 kg 26 5 lbs Fire Performance Type3 Type 10 Module Class A Spread of Flame Class B Burning Brand Operating Temperature 40 C to 85 C 1Minimum from strain relief to co...

Page 15: ...ng in landscape orientation is acceptable Module row to row shading in portrait orientation is prohibited Strain relief cable ties must not be removed If module cleaning is undertaken modules must be...

Page 16: ...visit www firstsolar com recycling for further details on the recycling program It is normal for the modules to exhibit visual irregularities which do not impact power Series 4A Modules with anti refl...

Page 17: ...otice Accordingly the reader is cautioned to verify that data sheets are current before placing orders or finalizing system permitting and or design Information furnished by Chosen Techno Solar Privat...

Page 18: ...Series 4 PV Module Mounting for UL Applications PD 5 308 FS Series PV Modules Reverse Current Overload PD 5 320 04 FS Series 4 PV Module Mounting PD 5 804 FS Series PV Module Cleaning Guidelines PD 5...

Page 19: ...to 2 2 Section 4 1 1 Added comment to Section 7 on cleaning risk of damage 12 17 2017 Added Section 10 for Doc References Revised order of Warnings in Sections 2 3 Added electrical ratings for FS 4xx...

Reviews: