Series 4 Module User Guide—North America 

| Page 1 of 17 

 

 
 

 

1

 

Introduction 

 

 

Chosen Techno Solar Private Limited Series 4 and Series 4A Modules are manufactured in state-of-the-art facilities using a highly 
innovative process that rapidly deposits thin films of semiconductor on glass. Series 4A modules are constructed identically to 
Series  4  modules  and  add  anti-reflective  coated  glass  to  Series  4  modules.  The  modules  have  been  designed  to  have  a  long 
operating  life  and  high  energy  yield  when  installed,  operated,  and  serviced  in  accordance  with  the  instructions  in  this  User 
Guide. Chosen Techno Solar Private Limited Series 4 and Series 4A Modules are electrically and mechanically compatible with 
one another, provided appropriate system design practices are employed. Series 4 and Series 4A Modules are not compatible 
with Chosen Techno Solar Private Limited Series 3 Modules within the same interconnected string. 

 
 

1.1  Before You Begin 

 

This document provides guidelines and information on Chosen Techno Solar Private Limited Series 4 and Series 4A Modules 
of  model  types  FS-4xxx,  FS-4xxxA,  FS-4xxx-2,  FS-4xxxA-2,  FS-4xxx-3,  and  FS-4xxxA-3  for  system  designers,  installers,  and 
maintenance personnel. Read this User Guide thoroughly before beginning any work related to the installation, operation, 
or maintenance of the Chosen Techno Solar Private Limited Series 4 or Series 4A Module. Only qualified personnel should 
install, operate, or maintain a PV module or system. 

 
 

Failure to follow installation and handling instructions may result in injury. 

 

Failure to maintain proper operating condition requirements for the modules will void the applicable warranties. 

 

This user guide pertains to modules installed within North America only. If a module is being installed outside of North America, 
contact  Chosen  Techno Solar Private Limited(technicalsupport@ctsonesolution.com) or visit  www.ctsonesolution.com for the 
User Guide appropriate for other geographic areas. 

 

Keep this User Guide for future reference. 

 

Guidelines related to system construction are beyond the scope of this document and are not covered in this document. 

 
 

1.2  Key Product Features 

 

 

High energy yields in real-world conditions. 

 

 

Size and weight that enables efficient handling and installation. 

 

 

Easy, quick-connect wiring for fast interconnection. 

 

 

Compatible with advanced 1500V plant architectures. 

 

 

Internationally recognized product certifications. 

 

 

Twenty-five year limited performance warranties. 

 
 
 
 
 
 

 

PD-5-200-04 NA | REV 3.1 | 0348_UG_NA_11JUL17 

Chosen Techno Solar Private Limited 

Summary of Contents for FS-4100

Page 1: ...User Guide User Guide Chosen Techno Solar Private Limited Series 4 Module North America REV 3 1 PD 5 200 04 NA 0348_UG_NA_11JUL17...

Page 2: ...1 System Derating Factors 5 4 Installation 6 4 1 Mounting 6 4 2 Module Orientation 8 4 3 Module Shading Considerations 8 4 4 Electrical Interconnection 9 5 Mechanical Specifications Drawings 12 6 Prop...

Page 3: ...lers and maintenance personnel Read this User Guide thoroughly before beginning any work related to the installation operation or maintenance of the Chosen Techno Solar Private Limited Series 4 or Ser...

Page 4: ...Chosen Techno Solar Private Limited module reverse current overload may result in module failure including module breakage Extreme and continuous reverse current overload conditions may cause a fire...

Page 5: ...ized or Listed by Underwriters Laboratories UL for their intended purpose Ensure the PV array open circuit voltage does not exceed 1500VDC 1000VDC for UL Canada Install modules with mounting systems t...

Page 6: ...2 FS 4105 2 FS 4107 2 FS 4110 2 FS 4112 2 FS 4100A 2 FS 4102A 2 FS 4105A 2 FS 4107A 2 FS 4110A 2 FS 4112A 2 Nominal Power 5 PMPP W 100 0 102 5 105 0 107 5 110 0 112 5 Voltage at PMA X VMPP V 66 2 67...

Page 7: ...tage VSYS V 1500 2 Maximum Series Fuse ICF A 4 0 1 As received and stabilized ratings at Standard Test Condition 1000W m2 AM 1 5 25 C Cell Temperature 10 2 1000V Listed for UL Canada 3 Measurement unc...

Page 8: ...d using approved hardware in the manner specified by the mounting instructions in Chosen Techno Solar Private Limited Application Note PD 5 320 04 NA Additional mounting systems may be approved for us...

Page 9: ...eight is 3 25 in 82 55 mm Modules used in UL Listed rooftop applications must be installed with approved mounting systems If alternate mounting means are employed this may affect the Listing fire clas...

Page 10: ...from diffuse shading for objects greater than 2 meters or 7 feet There is a low risk of module damage due to shading from walking or standing in front of operating modules or from parking or driving...

Page 11: ...lead wires tight at any time After installation the connected wire must not be under stress or tension Do not use junction box assembly or lead wire strain relief loops to secure excess wire or to be...

Page 12: ...re inverter ratings are appropriate When connecting Chosen Techno Solar Private Limited Series 4 and or Series 4A Modules in a series string ensure that the system design voltage and inverter design s...

Page 13: ...unded ungrounded floating and bi polar system architectures provided all appropriate design requirements are met and approved by First Solar FS Series PV Modules should not be used in positive grounde...

Page 14: ...on Span2 1314 mm 51 73 in Weight 12 kg 26 5 lbs Fire Performance Type3 Type 10 Module Class A Spread of Flame Class B Burning Brand Operating Temperature 40 C to 85 C 1Minimum from strain relief to co...

Page 15: ...ng in landscape orientation is acceptable Module row to row shading in portrait orientation is prohibited Strain relief cable ties must not be removed If module cleaning is undertaken modules must be...

Page 16: ...visit www firstsolar com recycling for further details on the recycling program It is normal for the modules to exhibit visual irregularities which do not impact power Series 4A Modules with anti refl...

Page 17: ...otice Accordingly the reader is cautioned to verify that data sheets are current before placing orders or finalizing system permitting and or design Information furnished by Chosen Techno Solar Privat...

Page 18: ...Series 4 PV Module Mounting for UL Applications PD 5 308 FS Series PV Modules Reverse Current Overload PD 5 320 04 FS Series 4 PV Module Mounting PD 5 804 FS Series PV Module Cleaning Guidelines PD 5...

Page 19: ...to 2 2 Section 4 1 1 Added comment to Section 7 on cleaning risk of damage 12 17 2017 Added Section 10 for Doc References Revised order of Warnings in Sections 2 3 Added electrical ratings for FS 4xx...

Reviews: