Service
7
18
DO NOT RETURN THIS PRODUCT TO YOUR RETAILER.
If you have difficulty assembling this product or have any
questions regarding the controls, operation, or maintenance
of this machine, you can seek help from the experts.
◊
Call a Customer Support Representative at
1-877-282-8684
Off-Season Storage
The following steps should be taken to prepare your pressure
washer for storage.
•
Drain all water from high pressure hose and wrap it onto
hose wrap.
•
Drain all water from the spray gun and wand by holding
spray gun in a vertical position with nozzle end pointing
down and squeezing trigger. Store in gun holder.
•
Wrap up and secure detergent siphon hose so it is
protected from damage.
•
Refer to engine manual for correct engine
storage instructions.
•
Store pressure washer in a dry, clean area. Do not store next
to corrosive materials, such as fertilizer.
When storing any type of power equipment in a poorly
ventilated or metal storage shed, care should be taken to
rust-proof the equipment. Using a light oil or silicone, coat
the equipment, especially cables and all moving parts of your
pressure washer before storage.
Pump
The manufacturer recommends using MTD Genuine Parts Pump
Guard (490-245-V011) or equivalent when storing the unit for
more than 30 days and/or when freezing temperatures are
expected. MTD Genuine Parts Pump
Guard (490-245-V011) is
environmentally friendly.
NOTE:
Using pump guard helps provide proper lubrication to
the internal seals of the pump regardless of temperature or
environment.
NOTICE:
Risk of property damage. Use only MTD Genuine Parts
Pump Guard (490-245-V011) or equivalent. Other products
could be corrosive and/or contain alcohol which may cause
pump damage.
1.
Turn off pressure washer and disconnect hoses from pump.
2.
Unscrew bottle valve from Pump Guard bottle and remove
seal.
3.
Screw bottle valve back onto bottle.
4.
Attach bottle to water inlet of pump.
5.
Squeeze bottle to inject contents into pump.
6.
With ignition switch off, simultaneously pull starter rope
and squeeze bottle. Repeat until protector fluid exits pump
outlet.
NOTE:
This step may require two people.
Specifications
* Rated Pressure and Rated Water Flow is within manufacturing
tolerance of (+/- 10%).
In a continued commitment to improve quality, the
manufacturer reserves the right to make component changes,
design changes, or specification changes when necessary and
without notice.
Summary of Contents for 26B-FFH5710
Page 21: ...Notes 21 ...
Page 70: ...Notas 69 ...