RZT-S Zero
10
4
Blades off: Right deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
16384
POST dynamic gating test
Controller failure
Overload: Slow down or
raise deck
Fault
Disables Blades and Drive
32768
Instantaneous under volt-
age
Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts
Stopped: Drive sensor
fault / Restart, if problem
persists contact service
Fault
Disables Blades and Drive
Interlock 1
code 1
Dual Throttle Input Signals
differ by more than
allowed tolerance
Poor connection, faulty
switch, damaged harness
Stopped: Drive sensor
fault / Restart, if problem
persists contact service
Fault
Disables Blades and Drive
Interlock 1
code 2
CRC check off throttle cali-
bration parameters has
failed
TPS needs to be re-cali-
brated
Stopped: Drive sensor
fault / Restart, if problem
persists contact service
Fault
Disables Blades and Drive
Interlock 1
code 4
Throttle not in neutral
when trying to close main
contactor
Drive pedal being acti-
vated, calibration error
Stopped: Drive sensor
fault / Restart, if problem
persists contact service
Fault
Disables Blades and Drive
Corrupt calibration param-
eters and VCM doesn't
know which throttle input
signal to use.
TPS needs to be re-cali-
brated
Stopped: Over-voltage /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
Controller voltages greater
than 59V for more than 5
continuous seconds.
Batteries over charged
Message
Message
type
Mower's action
Code
number
(engineering
screen)**
Trigger
Possible causes