CUB CRAFTERS
SECTION 9.1
CC11-100
SUPPLEMENT- FLOATS
Issued: 04/15/09
REPORT SC10000AFM
Date of Revision: 04/09/13
Page Number: 9
-
1
-
13
9.1.6.4.2
Preflight Right Fuselage, Wing, and Float
Right Fuselage .............................................. Check
Fuel Sump ...................................................... Drain
Flap Surface ................................... Check condition
Flap Hinges ................................................... Check
Aileron Surface ............................... Check condition
Aileron Hinges ............................................... Check
Wing Tip and Light......................................... Check
Vortex Generators ......................................... Check
Fuel Cap Vent ............................................... Check
Fuel Tank ........... Check supply and cap for security
Water Rudder and Cables............................. Check,
extend- retract
Main and Nose Gear (Amphibious Only) ....... Check
Float ..... Check for damage and water accumulation
(use bilge pump as necessary)
Bilge Rubber Plugs ......................................Secure
Oar ................................. Check stowed and secure
Float Hatches .... Cargo secure and hatches latched
9.1.6.4.3
Preflight Nose Section
Oil Door .......................................................... Open
Oil Quantity .......................... Check and cap secure
Engine Condition ........................................... Check
Oil Door .......................................................... Close
Propeller and Spinner .................................... Check
Air Inlets ........................................................ Check
Fuel Strainer (in front of firewall on left) .......... Drain
Fuel Drain (behind firewall on left) ................. Drain*
*For aircraft S/N 00264 and on only
NOTE
Remove rubber plugs which serve as stoppers on the
standpipe in each float compartment and pump out any
accumulation of water. Reinstall rubber plugs with
enough pressure for a snug fit.