7
10.0 Connectors and Controls
10.1 AC Power
AC Mains Inlet:
IEC socket with built in fuseholder and lighted ON/OFF switch
AC Mains Cord required:
Three wire 18 Gauge conductors with IEC socket and country
appropriate plug. Safety ratings such as UL or TUV are preferred.
Fuse type:
5X20mm Fast acting glass fuse rated at 3A 250V AC.
Example fuse: Littelfuse part no.
0235003.HXP
The fuse must only be replaced with one of the same type and current
rating.
10.2 DC Power
The CueScript prompters require a regulated supply of 12 volts DC rated at 4 amps. Alternatively, a
battery with sufficient capacity may be used. The prompter is designed to operate in the range 9V
–
18V DC.
Prompter Connector type:
4 pin XLR Male plug
Mating (cable) connector:
4 pin XLR Female socket
Pin Description
1
GROUND (connected to monitor chassis)
2
No Connection
3
No Connection
4
+12V DC
10.3 Composite Video In
Prompter Connector type:
75 Ohm BNC Socket
Mating (source) connector:
75 Ohm BNC Plug
Pin
Description
Center
Composite Video In (PAL, NTSC, or
SECAM)
Outer
Ground