Proper cleaning and sanitization of the complete Premium Cooler is critical to delivering great tasting water.
The Premium Cooler unit was assembled, tested and drained at the factory before shipping. The design includes a
unique internal water tank with a large surface area that stores the high quality product water the customer will drink.
Therefore this tank must be thoroughly cleaned of anything that could compromise the taste and quality of the water.
The inspection and first time start-up procedures for the Premium Cooler consist of five steps.
1. Unpack and inspect the unit for any shipping damage.
2. Wash the internal plastic reservoir, lid, and floats with dish soap. Rinse thoroughly.
3. Connect a feed water line (RO or DI water recommended) to the unit.
4. Sanitize the entire unit with chlorine.
NOTE Sanitizing is mandatory prior to installing the Premium Cooler.
5. Install and flush the water treatment components. (See appendix for details on water treatment configurations).
STEP ONE: Unpack and inspect
1. Unpack the Premium Cooler and check exterior for damage.
2. A Culligan IQR form is shipped with each unit. Fill out the IQR form and return to Culligan Quality Department.
3. Remove the top cover. Screws are located in the rear corners.
4. Remove the lower front panel. Two screws securing the lower front panel are located on the front, lower sides
near the floor. Depress the recessed tabs of the lower front panel (under the front-end of the unit) and pull out-
ward simultaneously to remove.
5. Visually inspect the internals of the unit for breakage and any wires that may have come loose during shipment.
STEP TWO: Wash the internal plastic reservoir
Figure 4. Internal plastic reservoir
1. Completely remove the internal plastic reservoir from the unit.
Inspection and First-Time Setup Procedures
C
B
A