16

01040707  B  07/21

There are several conditions that will cause the control to initiate a reconditioning cycle� The screen displays REGEN 

TONITE when the control has signaled for a reconditioning cycle� Regenerating is displayed while the control is 

reconditioning� The following are conditions that will call for reconditioning:

Reconditioning 

1�  When the Soft-Minder

®

 meter has recorded the passage of a predetermined number of gallons�

2�  At the preset time, when the number of days without a reconditioning cycle is equal to the regeneration interval 

(timeclock backup) setting�

3�  At the preset time, when 

REGEN TONITE

 is selected� The screen displays 

REGEN TONITE

4�  Immediately, when the 

REGEN NOW

 is selected� The screen displays 

REGENERATING

5�  Immediately, if power to the unit has been off for more than three (3) hours and time of day has been restored�
6�  At the preset time based on 

DAY-OF-WEEK

 Reconditioning setting�

Follow either procedure to initiate a manual reconditioning cycle� 

Delayed Reconditioning

Screen Display

Range

Changing the Setting

FILTERING  

JAN-01-18 12:01P

N/A

1�  At the 

HOME SCREEN

, press   and hold for at least 

three seconds, then release the button�

REGEN TONITE

JAN-01-18 12:01P

Regen 

Tonite

2�  The first line of the display will toggle between 

FILTERING

 

and 

REGEN TONITE

REGEN OFF   

JAN-01-18 12:01P

Regen 

Off

3�  To cancel a delayed reconditioning cycle, press and hold 

the   for three (3) seconds, then release the button� The 

screen displays 

REGEN OFF

Immediate Regeneration

Screen Display

Range

Changing the Setting

FILTERING  

JAN-01-18 12:01P

N/A

1�  At the 

HOME SCREEN

, press   and hold for at least 

five (5) seconds, then release the button�

REGEN NOW

JAN-01-18 12:01P

Regen 

Now

2�  The first line of the screen displays 

REGEN NOW

� The 

filter will initiate an immediate reconditioning cycle�

REGENERATING 

JAN-01-18 12:01P

N/A

3�  The first line of the screen displays 

REGENERATING

Summary of Contents for Aquasential Arsenic Reduction

Page 1: ...Aquasential Smart High Efficiency Water Filters Models from 2021 DCO 210240 07 30 21 CAT 01040707 Rev B 2021 Culligan International Company ...

Page 2: ... Analytical Laboratory is certified to perform coliform and E coli testing We strive to provide our customers with the testing they need at the lowest possible cost with the quickest turn around time STANDARD WATER TESTING For sizing systems and general chemical water characteristics WELL WATER TESTING Basic Realtor Drilling Surveilance Expanded Gold SPECIAL WATER TESTING Hemodialysis Scale Resin ...

Page 3: ...s 8 Application Operation 12 Arsenic Fact Sheet 14 Menu Navigation 15 Care Cleaning 18 When How to Bypass Your System 19 Things to Check Before You Call For Service 20 Performance Data Sheets 21 Records Data 29 Culligan Limited Warranty 30 3 01040707 B 07 21 Table of Contents ...

Page 4: ...E Note is used to emphasize installation operation or maintenance information which is important but does not present any hazard Caution CAUTION Caution is used when failure to follow directions could result in damage to equipment or property Warning WARNING Warning is used to indicate a hazard which could cause injury or death if ignored The CAUTION and WARNING paragraphs are not meant to cover a...

Page 5: ... or knowledge unless they have been given supervision or instruction Children should be instructed not to play with this appliance CAUTION If the power cord from the power supply to the unit looks or becomes damaged the cord and power supply should be replaced by a Culligan Service Agent or similarly qualified person in order to avoid a hazard CAUTION To reduce the risk of fire use only No 26 AWG ...

Page 6: ...ters have been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI CAN Stan dard 61 for material safety requirement only Not certified for contaminant reductions by WQA The Culligan Aquasential Smart High Efficiency 9 Filtr Cleer 10 Filtr Cleer 9 Filtr Cleer Outdoor and 10 Filtr Cleer Outdoor Water Filters have been tested and certified by WQA against NSF ANSI Standar...

Page 7: ...ional Company Culligan and its affiliates are protected by patents issued or pending in the United States and other countries Culligan reserves the right to change the specifications referred to in this literature at any time without prior notice Culligan Cullar Filtr Cleer Cullneu AccuSoft Culligan Man and www culligan com are trademarks of Culligan International Company or its affiliates License...

Page 8: ... Recharge Water Consumption Av 3 90 gal 140 gal Freeboard4 20 1 5 inches 19 1 5 inches Cullar Rated Service Flow Pressure Drop 4 0 gpm 2 0 psi 5 9 gpm 5 0 psi Drain Flow Maximum1 3 5 gpm 5 5 gpm pH Limitation 5 0 11 0 5 0 11 0 Recharge Time2 21 min 21 min Recharge Water Consumption Av 3 40 gal 110 gal Cullar Media Volume 0 73 cu ft 1 5 cu ft Cullsan Underbedding Media Amount 10 lb 1 ft3 20 lb 2 ft...

Page 9: ... 60 psi 20 60 psi Operating Temperature 33 120 F 1 48 C 33 120 F 1 48 C Electrical Requirements Control Valve 24VDC 1W 60 Hz 24VDC 1W 60 Hz Electrical Requirements Compressor 120VAC 60Hz 175W 245W continuous max 120 Volts 60Hz 175W 245W continuous max Drain Flow Maximum 10 gpm 5 5 gpm minimum required 10 gpm 8 0 gpm minimum required Regeneration Time Backwash 5 20 minutes 5 20 minutes Fast Rinse 5...

Page 10: ...Maximum Operating Pressure 20 60 psi 138 414 kPa 20 60 psi 138 414 kPa Operating Temperature 33 120 F 1 49 C 33 120 F 1 49 C Electrical Requirements Control Valve 24VDC 1W 60 Hz 24VDC 1W 60 Hz Electrical Requirements Compressor 120VAC 60Hz 175W 245W continuous max 120 Volts 60Hz 175W 245W continuous max Drain Flow Maximum 5 5 gpm 5 5 gpm Backwash 5 20 minutes 5 20 minutes Pause Draw Pause 1 min Ch...

Page 11: ...1 mg l recommended Manganese 0 01 mg l 1 mg l recommended Phosphate 0 40 mg l 01 mg l recommended Silica 30 mg l recommended Sulfate 100 mg l Hydrogen Sulfide None detectable Turbidity 5 NTU Fluoride 1 mg l Hardness 300 mg l Nuisance Bacteria None detectable for best performance and media life Tannins None detectable Operating Pressure 20 120 psi 138 862 kPa Operating Pressure Canada 20 90 psi 138...

Page 12: ... below the micron rating color caused by organics or dissolved solids Common applications follow Reduction of suspended matter in the water Reduction of particulate matter such as clay mud and fine sediment Prefiltration to remove oxidized iron prior to a water softening system Reduction of light sand and sediments After a retention tank when a Cul Cleer system with chemical feed is used for oxida...

Page 13: ...ns and balances an airhead within the tank Water entering the tank contacts air and starts the oxidation process Hydrogen Sulfide and iron begin to oxidize to sulfate and or a filterable particle Water flows through the filter tank where it contacts the CIM catalytic activated carbon media to complete the oxidation and filtration process In some hydrogen sulfide applications odors can develop with...

Page 14: ...enic Reduction Filter system is designed to reduce both pentavalent and trivalent forms of arsenic This treatment system was tested under laboratory conditions as defined in NSF ANSI 53 Drinking Water Treatment Units Health Effects and was found to reduce an arsenic challenge concentration of 10 mg l 100 ppb arsenic to less than 01 mg L 10 ppb of arsenic Challenge waters consisted entirely of pent...

Page 15: ...he highlighted option opens a new screen or accepts a changed setting CANCEL or X button returns to the previous screen or cancels a changed setting NOTE Hold down or to quickly scroll through the setting without repeatedly pressing the button The control must be returned to the HOME screen if settings are changed Use the Culligan Connect app to update the date or time Menu Navigation ...

Page 16: ... restored 6 At the preset time based on DAY OF WEEK Reconditioning setting Follow either procedure to initiate a manual reconditioning cycle Delayed Reconditioning Screen Display Range Changing the Setting FILTERING JAN 01 18 12 01P N A 1 At the HOME SCREEN press and hold for at least three seconds then release the button REGEN TONITE JAN 01 18 12 01P Regen Tonite 2 The first line of the display w...

Page 17: ...itioning time The screen displays two status messages FILTERING and REGEN TONITE 7 If the screen displays BYPASS then for a specified time the filter will be bypassed Press to select the total time the filter is to be in the bypass state MANUAL BYPASS OFF Off 30 min 60 90 120 180 Manual Bypass 8 Press and or to select the total time the filter is to be in the bypass state 9 Press to accept this se...

Page 18: ...ssemble it Call your Culligan Dealer Important Culligan water filters are sold for use on potable water only If at any time the water becomes contaminated such as during a boil water advisory the operation of the water filter should be discontinued until it is verified that the water is again potable To do this turn the blue knob in a clockwise position then call your Culligan dealer to have your ...

Page 19: ... Culligan water filter is a Cul Flo Valv Bypass valve To bypass the unit turn the blue knob clockwise To return to softened water service turn the blue knob counter clockwise Figure 1 Bypass valve Bypassed To BYPASS turn the blue knob clockwise see directional arrow on end of knob until the knob stops as shown in Figure 1 DO NOT OVERTIGHTEN Figure 2 Service valve Filter Water To return to SERVICE ...

Page 20: ...ur water supply is work ing Open a tap ahead of the conditioner outside tap to see if you have any water pressure If you have water pressure check the bypass valve If it is in the Service position put the system into bypass and call your Culligan dealer for service Increased Usage Guests family additions new water using appliances etc will result in more water usage and may require additional prog...

Page 21: ...enge Concentration Reduction Requirement Chlorine 2 0 mg L 10 50 The Culligan Aquasential Smart High Efficiency Cullar filters have been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 42 for the effective reduction of chlorine taste and odor up to 120 000 gallons for the 9 filter and 180 000 gallons for the 10 filter as verified and substantiated by test...

Page 22: ...20 125 psi 140 862 kPa Electrical Characteristics 24 VDC 21 6 Watts Water Press Range Canada 20 90 psi 140 620 kPa The Culligan Aquasential Smart High Efficiency Cullneu filters have been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI CAN Standard 61 for material safety requirement only Not certified for contaminant reductions by WQA Performance Indicator If wate...

Page 23: ...ay vary Name of Substance Influent Challenge Concentration Reduction Requirement Particulate Class IV particles 15 μm to 30 μm At least 1 000 particles mL 85 The Culligan Aquasential Smart High Efficiency Filtr Cleer filters have been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 42 for Class IV 15 μm to 30 μm particulate reduction as verified and subst...

Page 24: ...140 830 kPa Electrical Characteristics 24 VDC 21 6 Watts Water Press Range Canada 20 90 psi 140 620 kPa The Culligan Aquasential Smart High Efficiency Empty Water filters have been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI CAN Standard 61 for material safety requirement only Not certified for contaminant reductions by WQA No media or underbedding has been qu...

Page 25: ...Range 20 120 psi 140 830 kPa Electrical Characteristics 24 VDC 21 6 Watts Water Press Range Canada 20 90 psi 140 620 kPa The Culligan Aquasential Smart High Efficiency Empty w FP Water filters have been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI CAN Standard 61 for material safety requirement only Not certified for contaminant reductions by WQA No media or un...

Page 26: ... substances listed below The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 Name of Substance Influent Challenge Concentration Reduction Requirement Iron 3 0 5 0 mg L 0 3 mg L The Aquasential Smart High Efficiency 10 and 12 Iron Cleer filters h...

Page 27: ...10 Fiberglass Hydrogen Sulfide 0 3 mg L 98 9 8 2 mg L 0 091 mg L Iron 98 7 10 4 mg L 0 14 mg L 10 Quadra Hull Hydrogen Sulfide 0 3 mg L 98 9 8 2 mg L 0 091 mg L Iron 98 7 10 4 mg L 0 14 mg L The Aquasential Smart High Efficiency Sulfur Cleer 10 fiberglass and Quadra Hull filters have been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 42 for the effectiv...

Page 28: ... 10 10 0 010 96 12 99 14 Pentavalent Arsenic pH 6 5 0 10 10 0 010 91 83 97 18 Pentavalent Arsenic pH 8 5 0 10 10 0 010 93 82 98 02 The Culligan Aquasential Smart High Efficiency Arsenic 12 14 and 16 filter and Aquasential Smart High Efficiency Arsenic 12 14 and 16 Outdoor filter have been certified by IAPMO R T against NSF ANSI Standard 372 CSAB483 1 and NSF ANSI Standard 53 for the effective redu...

Page 29: ...h Neutralizing Media Cullneu only Media Life estimated Owner Maintenance Replace Cartridge Filter s Replenish chlorine solution Sulfur Cleer only Water Analysis Hardness ____________________ grains gallon TotalDissolvedSolids TDS______________________mg l pH level acidity _____________________ S U Alkalinity_______________________________grains gallon Iron _______________________________ mg l Mang...

Page 30: ...oduct performance specifications are furnished with each water conditioning unit TO THE EXTENT PERMITTED BY LAW CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE TO THE EXTENT REQUIRED BY LAW ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE ONE YEAR PERIOD SPECIFIED ABOVE FOR THE ENTIRE CONDITIONER As a...

Reviews: